Temperature Sensors.
Room temp.(T1) sensor,
Indoor coil temp.(T2) sensor,
Outdoor coil temp.(T3) sensor,
Outdoor ambient temp.(T4) sensor,
Compressor exhaust temp.(Te) sensor.
Measure the resistance value of each winding by using the multi-meter.
Some frequently-used R-T data for Te sensor:
Temperature (0°F)
41°F/5°C
Resistance Value
141.6
(KΩ)
Some frequently-used R-T data for T1, T2, T3 and T4 sensor:
Temperature
41°F/5°C
(0°F)
Resistance
26.9
Value (KΩ)
59°F/15°C
77°F/25°C
95°F/35°C
88
56.1
36.6
50°F/10°C
59°F/15°C
68°F/20°C
20.7
16.1
12.6
VMH SerieS
140°F/60°C
158°F/70°C
13.8
9.7
77°F/25°C
86°F/30°C
10
8
43
44
Heat Controller, Inc.
176°F/80°C
194°F/90°C
212°F/100°C
6.9
5
3.7
104°F/40°C
122°F/50°C
140°F/60°C
5.2
3.5
2.4