(2) Outdoor Unit
1. LV-B1861CL/2461CL
2. LV-B2461HL
BL
CAPACITOR
R
RD
COMP.
S
C
REVERSING
COIL
BK
BK
BK
BK
3
4
5
6
TO INDOOR UNIT
CONVERTIBLE(HEAT PUMP)
BL
R
C
COMP.
S
RD
BR
BL
TO INDOOR UNIT
CONVERTIBLE(COOLING ONLY)
CAPACITOR
YL
BR(OR)
FAN
MOTOR
THERMISTOR
GN/YL
T/B
L3 L2 L1
YL
BK
GN/YL
TERMINAL
7
BLOCK
(OUTDOOR)
YL
BR(OR)
FAN
MOTOR
H
F
C
CAPACITOR
T/B
BK
BR
TERMINAL
3
4
BLOCK
(OUTDOOR)
3. LV-B1861HL
BL
R
RD
COMP.
S
C
3
4
TO INDOOR UNIT
CONVERTIBLE(HEAT PUMP)
–12–
GN/YL
CAPACITOR
CAPACITOR
FAN
MOTOR
REVERSING
THERMISTOR
VALVE
GN/YL
BK
BK
L3 L2 L1
BK
BK
YL
BK
GN/YL
TERMINAL
5
6
7
BLOCK
(OUTDOOR)
YL
BR(OR)