Congratulations on your purchase of a Renkus-Heinz SG Series loudspeaker system. Your SG Series loud-
speaker has been designed to provide you years of trouble-free high performance listening pleasure. We hope
you enjoy it.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in ac-
cordance with the manufacturer's instructions
8. Do not install near any heat sources such as radia-
tors, heat registers, stoves, or other apparatus (in-
cluding amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The
wide blade or the third prong is provided for your
safety. If the provided plug does not fit into your out-
let, consult an electrician for replacement of the obso-
lete outlet.
10. Protect the power cord from being walked on or
pinched particularly at plugs, convenience recepta-
cles, and the point where they exit from the appara-
tus.
11. Make sure the power cord remains readily acces-
sible at all times.
The lightning flash with arrow-
head symbol, within an equilat-
eral triangle, is intended to alert
the user to the presence of unin-
sulated "dangerous Voltage" within the prod-
uct's enclosure that may be of sufficient
magnitude to constitute a risk of electric shock
to humans.
IMPORTANT MOUNTING INSTRUCTIONS
To ensure proper air movement for the cooling of the amplifier module, we recommend a minimum of 2 to 3 feet
of clearance in front of the loudspeaker and at least 3 to 4 inches of clearance from the other cabinet surfaces.
Your SG Series loudspeaker was designed to be mounted in an upright position. Please do not place it on its
side on the floor.
Safety certifications do not include methods for mounting loudspeakers.
2
INTRODUCTION
12. Only use attachments/accessories specified by
the manufacturer.
13. Unplug this apparatus during lightning storms or
when unused for long periods of time.
14. Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not operate
normally, or has been dropped.
"WARNING - TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE THIS APPA-
RATUS TO RAIN OR MOISTURE"
"CAUTION: THESE SERVICING INSTRUCTIONS
ARE FOR USE BY QUALIFIED SERVICE PERSON-
NEL ONLY. TO REDUCE THE RISK OF ELECTRIC
SHOCK DO NOT PERFORM ANY SERVICING
OTHER THAN THAT CONTAINED IN THE OPERAT-
ING INSTRUCTIONS UNLESS YOU ARE QUALI-
FIED TO DO SO".
The exclamation point, within
an equilateral triangle is in-
tended to alert the users to the
presence of important operating
and maintenance (servicing) instructions in the
literature accompanying the product.
Installing a PF1 series power amplifier into a SGX Series loudspeaker
Adding a power amplifier to a CFX loudspeaker is a quick and easy process. Before you b
have a clean workspace, preferably one with a soft, non-scratching surface and a #2 Phillips Screwdriver.
A step-by-step procedure follows:
1. Using the Phillips screwdriver, remove the eight
screws holding the connector plate to the rear of the cabi-
net. Save the screws, you'll need them to install the am-
plifier.
2. Gently remove the input connector plate from the cabi-
net. You can use a SpeakOn connector as a handle, if
you want
3. Remove the white quick disconnect connector from the
PC board on the inside of the input connector plate by
squeezing the sides of the connector and pulling up. Set
the input connector plate aside and save it in case you
ever need to switch the loudspeaker back to its externally
powered configuration.
4. Prepare PF1-200 amplifiers for installation by setting
the switches on the side of the amplifier according to the
table below. Improper settings on these switches can lead
to loudspeaker damage which is not covered by our war-
ranty.
HIGH PASS
LOW PASS
FILTER
FILTER
SG61
90
20K
SG81
60
20K
SG121
30
20K
SG151
30
20K
SG12S
30
100
Prepare PF1-500 amplifiers for installation by setting the
single switch to either "Flat" or "100 Hz Filter". Use "Flat"
for full range operation,100 Hz Filter when the amplifier is
being installed in a SGX12S subwoofer. PF1-200R and
PF1-500R RHAON empowered amplifiers do not have
these switches as these settings are controlled remotely.
5. Plug the white quick disconnect connector into the
matching socket on the rear of the power amplifier. The
socket is keyed, so you will have to properly align the
connector with the socket. Make sure that both sides of
the connector latch into place.
6. Insert the power amplifier into the opening in the back
of the loudspeaker and reinstall the eight screws to se-
cure the amplifier into the cabinet. You can use an XLR
connector as a handle.
6
egin,
make sure you
Step 2
Step 1
Step 3
Step 4
Step 5
Step 6