Sharp R-880B Service Manual page 23

Double grill convection microwave oven
Hide thumbs Also See for R-880B:
Table of Contents

Advertisement

LSI(IZA927DR)
The I/O signal of the LSI(IZA927DR) are detailed in the following table.
Pin No.
Signal
1
C1
2
VL1
3-5
AN7-AN5
6
AN4
7
AN3
8
AN2
9
AN1
10
AN0
11
P57
12
P56
13
P55
14-18
P54-P50
19
P47
20
P46
21
P45
22
P44
23
INT1
24
INT0
DESCRIPTION OF LSI
I/O
IN
Terminal not used.
IN
Power source voltage input terminal.
Standard voltage for LCD.
IN
Heating constant compensation terminal.
IN
Terminal not used.
IN
Temperature measurement input: OVEN THERMISTOR.
By inputting DC voltage corresponding to the temperature detected by the
thermistor, this input is converted into temperature by the A/D converter built into
the LSI.
IN
Input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal.
Door opened; "L" level signal.
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected
to the A/D converter built into the LSI.
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This
input is an analog input terminal from the AH sensor circuit, and connected to
the A/D converter built into LSI.
This input is an analog input terminal from the AH sensor circuit, and connected
to the A/D converter built into the LSI.
OUT
Timing signal output terminal for temperature measurement(OVEN
THERMISTOR).
"H" level (GND) : Thermistor OPEN timing.
"L" level (-5V) : Temperature measuring timing. (Convection cooking)
OUT
Signal to sound buzzer.
A: key touch sound.
B: Completion sound.
C: When the temperature of the oven
cavity
reaches
temperature in the preheating mode,
or when the preheating hold time (30
minutes) is elapsed.
OUT
Timing signal output terminal for temperature measurement(OVEN
THERMISTOR).
"H" level (GND) : Thermistor OPEN timing.
"L" level (-5V) : Temperature measuring timing. (Convection cooking)
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
IN
Signal coming from touch key.
When any one of G12 line keys on key matrix is touched, a corresponding signal
from P40, P41, P72, P73, P74, P75, P76 and P77 will be input into P47. When no
key is touched, the signal is held at "L" level.
IN
Signal similar to P47.
When any one of G11 line keys on key matrix is touched, a corresponding signal
will be input into P46.
IN
Signal similar to P47.
When any one of G10 line keys on key matrix is touched, a corresponding signal
will be input into P45.
IN
Signal similar to P47.
When any one of G9 line keys on key matrix is touched, a corresponding signal will
be input into P44.
IN
Terminal not used.
IN
Signal to synchronized LSI with commercial power source
frequency(50Hz).
This is basic timing for time processing of LSI.
Description
the
preset
21
0.12 sec
A
2.4 sec
B
1.2 sec
1.2 sec
H: GND
C
L
20 msec.
R-880B
H : GND
L (-5V)

Hide quick links:

Advertisement

Table of Contents
loading