Intake Air Filter
To properly maintain the operational performance of
your PTAC unit, it is extremely important that the inlet
air filter be cleaned once per month or more often if
operated in dusty or dirty locations or conditions. The
intake air filter is constructed of durable polypropylene.
The "air intake" air filter can be easily inserted into the
cabinet front using the cabinet filter guides. The intake
air grille swings out for easy access to the filter. Before
cleaning the intake filter, turn the unit off by setting the
mode switch to the OFF position. Filter should be
cleaned as required.
The following procedure is used to remove the intake
filter:
1. Open the intake grille by grasping the top intake lou-
ver.
2. Pull the intake grille open.
3. Slide filter upward and remove.
4. Clean filter with vacuum or with running water.
Reverse this procedure to reinstall the filter.
NOTE: Available accessory filter kits are FK10B (air
intake filter - 10 per pack) and CFK10B
(charcoal filter - 10 per pack). The charcoal filters will
greatly improve the quality of the air by absorbing odors
from tobacco smoke, mold, mildew, etc. Both filters are
permanent and cleanable. Contact your sales person
for details.
Intake Filter Removal

Maintenance and Cleaning

MONTHLY MAINTENANCE AND CLEANING
`
Vent Screen
Before cleaning the vent screen, disconnect power to
the unit by unplugging the power cord at the wall outlet
or subbase, or disconnect power at the fuse box or
circuit breaker. If unit is operated with vent door
closed, the vent screen does not need to be cleaned.
1. Remove the cabinet front as described in Front Re-
moval.
2. Remove the six screws securing the chassis to the
wall sleeve.
3. Slide the chassis out of the wall sleeve far enough so
that the vent screen is accessible.
4. Remove the three screws securing the vent mesh
screen to the partition panel.
5. Clean and replace the vent screen, slide the chassis
back into the wall sleeve, secure it in place with six
screws and reinstall the front cabinet.
Vent - (Left Side Unit)
Cabinet Front
The cabinet front and discharge air grille can be cleaned
with a water dampened cloth . Under no circumstances
should hydrocarbon-based cleaners (e.g. acetone,
benzene, naphtha gasoline, etc.) be used to clean the
front or air grilles. Use care when cleaning the control
area.