What To Do If Things Go Wrong (1) Self Help; What To Do If Things Go Wrong (2) Professional Service; Troubleshooting - Creda FLORIDA PLUS Installation And User Manual

Electric shower
Table of Contents

Advertisement

SELF HELP
If the shower is not working satisfactorily, make the following checks before calling out the installer.
Any one of these adjustments could restore the performance.
The shower cycles
from HOT to COLD
Water too HOT
Water too COLD
Spray pattern poor
Water takes longer
to heat up
Water goes cold
while using
shower
Broken parts
PROFESSIONAL SERVICE
If the previous "Self Help" checks fail to restore the performance, you should seek professional help.
The person who installed the shower is probably the best one to investigate and correct it and is
certainly the person to contact if you have had a problem in the guarantee period.
The following additional checklist is provided for the benefit of the qualified service person.
WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR
BEFORE REMOVING THE COVER TO MAKE CHECKS
Water too HOT
Water too COLD
No control over
water flow
Water discharges
from pressure
relief valve
Water does not
flow when
button "B" pressed
WHAT TO DO IF THINGS GO WRONG (1)
The shower temperature is set too hot causing the thermal cut-out (safety
device) to operate.
Turn knob "C" clockwise to increase water flow.
Slowly increase the water temperature by turning knob "C" anti-clockwise until a
comfortable showering temperature has been reached.
You MUST WAIT approximately 20 seconds for each adjustment to take effect.
"HALF HEAT
" put symbol in setting may need to be selected.
Increase water flow by adjusting knob "C" clockwise.
"HALF HEAT
" setting may need to be selected.
Increase flow of water supply e.g. fully open service valve or stop cock.
Check hose is not kinked restricting the water flow.
Clean shower handset.
Check power is on by neon being illuminated.
Decrease water flow by adjusting knob "C" anti-clockwise.
"FULL HEAT
" setting may need to be selected.
Clean the shower handset.
Thermal cut-out has operated after previous use ("overheat" light is still on)
(automatically resets when unit cools down)
"FULL HEAT
" setting may need to be selected.
Check neon light is on.
Check water pressure has not fallen so far as to let pressure switch cut out,
e.g. Another tap drawing water off.
Raise position of shower handset.
Please contact our After Sales Service Department.
WHAT TO DO IF THINGS GO WRONG (2)
Water flow restricted. possible blockage in filter of solenoid valve.
Switch off water, loosen inlet connection to solenoid and replace.
Check circuit through thermal cut-out.
Check circuit through microswitches on the pressure switch.
Check each element circuit.
Check tightness of electrical connections.
Undo headworks of stabiliser valve.
Check stabiliser is in place and remove any debris in valve.
Check for cause of high pressure and remove it.
Blockage on outlet e.g. blocked shower handset.
Replace the pressure relief disc (not covered by guarantee).
Check circuit through solenoid coil. If defective then replace.
Check circuit through switch. If defective then replace.
Power supply not reaching shower.