DT Housing
ASM
Pressure
Q-Spring
Switch
Hinge Pin
Inner Tub Cap
Inlet valve
ASM
Power
Cord
Q-Spring
Fuse
Hinge Pin
holder
Tub Cover
Disassemble the power cord.
Remove two inlet valve screws and pull up inlet valve from D.T
housing assembly.
Be careful that the silicon rubber of D.T housing assembly for
sealing is not missing.
Inlet valve assembly is disassembled by pulling out the lead wire
attached on inlet valve assembly.
To disassemble D.T housing assembly, loosen the three screws
tightened with the top cover and then pull the assembly back
slopped down.
Remove the Pressure Switch.
Fuse is located in the fuse holder.
For fuse replacement use the following rated fuse
* Rating of fuse
- 250V 8A fusing type for 220-240V product (time delay type)
- 125V 12A fusing type for 100-127V product (time delay type)
3) Disassembly of Lid Assembly, Top Cover,
Tub Cover & Inner Tub
Remove Q-spring & two hinge pins then disassemble the lid
assembly
Remove two screw caps using a sharp tool and loosen the two
front special screws and the two fixing screws in the back side
and disassemble top cover from washing machine.
Remove tub cover fixing screws then disassemble
the tub cover.
Remove the Inner tub cap asmebly with "_" type driver.
Remove the hub fixing nut by a special tool.
Disassemble the inner tub.
Shaft
Rotor Nut
Hub fixing nut
40
Inner Tub Cap
Hub Fixing Nut
Out Tub
Inner Tub
Bearing Housing ASM
Rotor
Stator