Rear Vent, Wall Mounted Termination Graph; Standard Rear Vent, (No Elbows Or Offsets); Rear Vent, Wall Mounted Termination (Two Elbows) - Montigo L52DF Installation & Maintenance Manual

L-series residential fireplace
Table of Contents

Advertisement

L52DF* Indoor Gas Fireplace
notes Wall Mounted Terminations: REAR VENT
All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graphs,
see Figure 15.
Fireplace must be converted to Rear Vent configuration prior to
running vent, see Figure 9 and 9a.
The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of the
termination and the horizontal run from the fireplace flue collar to the wall
flange of the termination. Plot on the Venting Graph Figure 15 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 102" and the horizontal
run to the wall flange of the vent termination is 108", this would be
an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 42" and the horizontal
run to the wall flange of the vent termination is 108",this would
nOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and
the horizontal run to the wall flange of the vent termination is 168",
this would nOT be an acceptable installation.
Acceptable vent run
within non-shaded area.
B
55"
40"
Figure 15. Rear Vent Venting Graph for wall mounted terminations.
WARnIng
An inspection of the explosion relief flappers and door MUST be made prior to
lighting the fireplace. A faulty seal on the door gasket and/or explosion ports will
result in products of combustion leaking into the living space and may result in
carbon monoxide poisoning.
Page 16
Installation
A
C
Unacceptable vent run
within shaded area.
If your installation does not fall
within the venting graph parameters,
please contact a local Montigo
dealer for Power Venting options.
Flex or Rigid
Section
6"
Figure 15a. Rear Vented, wall mounted Multi-elbow termination
installation. Installation for L52DF* must have a minimum vertical rise
of 52".The vent run must comply with the Venting Graph for Rear vent,
wall mounted terminations, Figure 15.
28" Max.
19"
Min.
55" Min.
12"
Max.
33"
XG0185 - 100511.1