Lamp Specifications - Optoma EP735 Service Manual

Projection system
Hide thumbs Also See for EP735:
Table of Contents

Advertisement

EzPro735
EzPro735

6-1 Lamp Specifications

Operating and Measurement Conditions
w
Ballast type
w
Rated lamp wattage
w
Burner position
w
Burning position
Temperature
w
Lamp burner Mo foil, back
w
Lamp burner Mo wire
w
Lamp burner Mo foil, front
Validation of max. permissible temperatures by reference thermocouple measurement based
on a reference lamp housing.
Typical Burner Characteristics (initial)
w
UV-output
w
UV-output through dichroic reflector
w
Total visible flux
w
IR
Average Lamp Life and Lumen Maintenance
w
Switching cycle
w
Lamp life time
w
Lamp life
Rise Time
Rise time to 80% of the stabilized luminous output is < 90 sec without forced convection.
Extensive cooling of the bulb during lamp run-up phase has to be avoided.
Hot Restrike
If the unit has been off for more than 60 sec. the lamp must restrike.
(Ignition voltage 20 kV +/- 3 kV)
No forced cooling is required following lamp switch-off.
S
M
6 - 2
ERVICE
ANUAL
Test conditions stable at 120W with
OSRAM PT VIP 120 AC/100-240 H ballast
120 W (cf. note in item 1. Product Scope)
0° to +20° (0° optical axis horizontal)
horizontal
< 350°C
< 400°C
< 350°C
UVA (315-400 nm) 7 W typical
UVB (280-315 nm) < 0,1 W
UVC (248-280 nm) < 0,01 W
(248-400 nm) 2 W typical
(400-780 nm) 30 W typical
(780-2500 nm) 30 W typical
3.5 hrs on 0.5 hrs off
1000 hrs typical
Lamp output >50% of initial lumen output
Lumens measurement as described in 2.9.