Optoma EX612 Service Manual page 44

Projection system
Hide thumbs Also See for EX612:
Table of Contents

Advertisement

2.Bright pixel
Procedure
Inspection item
Criteria
3. Dark pixel
Procedure
Inspection item
Criteria
- Test equipment: video generator.
- Test signal: analog 1024x768@60Hz.
- Test Pattern: Gray 10
- Bright pixel check.
- Bright pixel is unacceptable under gray 10
pattern.
Please refer to the figure in 4-4 Test Condition
for Frame and Active area.
Note: The defect criteria follows TI specification.
- Test equipment: video generator.
- Test signal: analog 1024x768@60Hz.
- Test Pattern: White pattern
- Dark pixels check.
- White pattern
- Adjacent dark pixel.
- The number of the dead pixels should be less or
equal to 4 pixels.
- Adjacent pixel with each other is unacceptable.
Note: The defect criteria follows TI specification.
EX612/EX615/EW615i/EX612i/EX615i
Gray 10
White pattern
EX615i
Confidential
4-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ex615Ew615iEx612iEx615i

Table of Contents