Low Air Pressure Warnings
The dive computer will warn you with three (3) audible double beeps and a blinking
pressure display when the cylinder pressure reaches 50 bar/700 psi.
Three (3) double beeps are also heard when the cylinder pressure goes down to the
user-selected alarm pressure, and when the remaining air time reaches zero.

6.1.4. Ascent rate indicator

The ascent rate is shown graphically along the right hand side. When the maximum
allowed ascent rate is exceeded, the lower segments start to blink with the top segment
staying solid, indicating that the maximum ascent rate has been exceeded continuously
or that the current ascent rate is significantly above the allowed rate.
Continuous ascent rate violations will result in Mandatory Safety Stops. When Recom-
mended Deep Stop is enabled, the length is indicated in seconds.
NORMAL
ASCENT
RATE.
ACTIVATED BACKLIGHT,
ALARM AND A BLINKING ASCENT
RATE BAR GRAPH INDICATE YOU
ARE ASCENDING FASTER THAN 10
M/MIN. YOU ARE ADVISED TO
MAKE A MANDATORY SAFETY
STOP WHEN YOU REACH A
DEPTH OF 6 M.