Haier AD182AMERA Service Manual page 29

Commercial air conditioning
Hide thumbs Also See for AD182AMERA:
Table of Contents

Advertisement

INSTALLATION PROCEDURE
ELECTRICAL WIRING
When connecting the cord before installing the indoor unit
Insert the cord from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cord ends fully into terminal block, then
tighten the screws.
Pull the cord slightly to make sure the cords have been properly inserted and
tightened.
After the cord connection, never fail to fasten the connected cord with the
wiring cover.
Note: when connecting the cord, confirm the
terminal number of indoor and outdoor units
carefully. If wiring is not correct, proper operation
can not be carried out and will cause defect.
After connecting the piping, check the joints for gas leakage with gas leakage detector.
HOW TO CONNECT WIRING TO THE TERMINALS
A. For solid core wiring (or F-cable)(Fig.17A)
(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the exposed
solid wire.
(2) Using a screwdriver, remove the terminal screw (s) on the terminal board.
(3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
(4) Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal screw using
a screw driver.
B. For strand wiring (Fig.17B)
(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 10mm of the exposed
strand wiring.
(2) Using a screwdriver, remove the terminal screw (s) on the terminal board.
(3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.
(4) Position the round terminal wire, and replace and tighten the terminal screw using a screw driver.
Fig. 17
A. Solid
Insulation
After passing the connection cord and power cable through the
insulation tube, fasten it with the cord clamp, as shown in Fig.18
Fig. 18
Insulation tube
Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube.
Commercial Air Conditioner
CAUTION
!
B. Strand wire
Loop
Cord clamp
Round
terminal
Screw with
special washer
Round
terminal
Terminal
board
Wire
-29-
Model: AU182AFERA
AD182AMERA, AS182AVERA
Screw with
special washer
Round
terminal
Wire

Advertisement

Table of Contents
loading

This manual is also suitable for:

As182averaAu182afera

Table of Contents