Sharp ER-A440 Service Manual page 11

Electronic cash register
Hide thumbs Also See for ER-A440:
Table of Contents

Advertisement

3) Pin description
PIN
SIGNAL
SYMBOL
No.
NAME
OUT
1
2
3
VSS
VSS
4
P10
ERC
OUT
5
P11
LDRQ
OUT
6
P12
/SHEN
7
P13
/FRES
OUT
8
P14
BUSY
9
10
11
P17
12
D0
D0
13
D1
D1
14
D2
D2
15
D3
D3
16
D4
D4
17
D5
D5
18
D6
D6
19
D7
D7
20
VSS
VSS
21
A0
A0
OUT
22
A1
A1
OUT
23
A2
A2
OUT
24
A3
A3
OUT
25
A4
A4
OUT
26
A5
A5
OUT
27
A6
A6
OUT
28
A7
A7
OUT
29
A8
A8
OUT
30
A9
A9
OUT
31
A10
A10
OUT
32
A11
A11
OUT
33
A12
A12
OUT
34
A13
A13
OUT
35
A14
A14
OUT
36
A15
A15
OUT
37
VSS
VSS
38
A16
A16
OUT
39
A17
A17
OUT
40
A18
A18
OUT
41
A19
A19
OUT
42
A20
A20
OUT
43
A21
A21
OUT
44
A22
A22
OUT
45
A23
A23
OUT
46
VSS
VSS
47
/WAIT
/WAIT
48
OUT
49
/BREQ
/BREQ
50
P33
DOPS
51
P34
/DR0
OUT
52
P35
/DR1
OUT
53
P36
NU
54
P37
NU
55
VCC
VCC
56
P40
/IFV
57
IN/
FUNCTION
RESET INPUT from CKDC WUTH
IN
BUFFER
NON-MASKABLE INTERRUPT INPUT
IN
FOR SSP INTERRUPT INPUT
GND
EVENT READ CANCEL (to CKDC)
LOAD REQUEST (to CKDC)
IN
SHIFT ENABLE (from CKDC)
FISCAL MEMORY RESET (NU)
IN
FISCAL MEMORY BUSY (NU) Pull-up
FISCAL MEMORY READY (NU)
IN
Pull-up
POP-UP DISPLAY SENSOR (NU)
IN
Pull-up
IN
GND Nu
I/O
DATA BUS 0
I/O
DATA BUS 1
I/O
DATA BUS 2
I/O
DATA BUS 3
I/O
DATA BUS 4
I/O
DATA BUS 5
I/O
DATA BUS 6
I/O
DATA BUS 7
GND
ADDRESS BUS 0
ADDRESS BUS 1
ADDRESS BUS 2
ADDRESS BUS 3
ADDRESS BUS 4
ADDRESS BUS 5
ADDRESS BUS 6
ADDRESS BUS 7
ADDRESS BUS 8
ADDRESS BUS 9
ADDRESS BUS 10
ADDRESS BUS 11
ADDRESS BUS 12
ADDRESS BUS 13
ADDRESS BUS 14
ADDRESS BUS 15
GND
ADDRESS BUS 16
ADDRESS BUS 17
ADDRESS BUS 18
ADDRESS BUS 19
ADDRESS BUS 20
ADDRESS BUS 21
ADDRESS BUS 22
ADDRESS BUS 23
GND
IN
Wait signal from MPCA
Bus control request acknowl edge (Nu)
IN
Bus control request (Nu) pull-up
IN
Drawer open sencer signal
Drawer open drive signal
Option drawer 1 drive signal
IN
(Nu) GND
IN
(Nu) GND
+5V
IN
Slip printer enable (Nu) pull-up
Printer (Dp-730) timing signal from
IN
MPCA
PIN
SIGNAL
SYMBOL
No.
NAME
58
P42
/TOF
59
P43
/BOF
60
61
P45
/NEJ
62
63
P47
/NER
64
VSS
VSS
65
P50
TRG1
66
P51
/PSTOP
67
P52
/CKDCR2
68
P53
OPDS
69
P54
FVPON
70
P55
FMRS
71
P56
/SLIPLMP
72
P57
/STOP
73
74
75
76
77
78
79
80
81
VSS
VSS
82
AVSS
AVSS
83
P70
VPJ
84
P71
VPR
85
P72
VPTEST
86
P73
87
AVCC
AVCC
88
VCC
VCC
89
P80
/iRQ0
90
91
P82
/iRQ2
92
P83
SCK2
93
P84
RXD
94
P85
TXD
95
96
97
VSS
VSS
98
EXTAL
EXTAL
99
XTAL
XTAL
100 VSS
VSS
101
102 E
103 /AS
/AS
104 /RD
/RD
105 /HWR
/WR
106 /LWR
107 /RFSH
/RFSH
108 VCC
VCC
109 MD0
MD0
110 MD1
MD1
111 MD2
MD2
112 /STBY
/STBY
4 – 4
IN/
FUNCTION
OUT
IN
Slip TOF signal (Nu) pull-up
IN
Slip BOF signal (Nu) pull-up
Printer (Dp-730) Reset signal from
IN
MPCA
IN
Near END signal jounal
CKDC interface shift enable signal
IN
(NU) GND
IN
Near END signal receipt
GND
OUT
Dot pulse adjust signal
OUT
Nu
OUT
Nu
IN
Nu (GND)
OUT
Nu
IN
Nu (GND)
OUT
Nu
OUT
Nu
ER signal for RS232 (Equipment
OUT
Ready)
IN
DR signal for RS232 (Data set Ready)
CS signal for RS232 (Clear to Send)
IN
IN
CD signal for RS232 (Carrier Detect)
RR signal for RS232 (Ready to
OUT
Receive) (Nu)
OUT
RS signal for RS232 (Request to Send)
CI signal for RS232 (Calling Indicator)
IN
Printer (Dp-730) Home position pulse
IN
GND
IN
GND
IN
Validation sensor journal (NU) GND
IN
Validation sensor receipt (NU) GND
IN
+24V test input
IN
Validation sense signal (Nu) GND
IN
+5V
+5V
IN
Interrupt signal 0 from MPCA
Interrupt signal from OPTION PWB
IN
IN
Interrupt signal (Nu) pull-up
OUT
CKDC & FMC i/F sync shift clock
IN
RS232C RECEIVE DATA
OUT
RS232C SEND DATA
CKDC, Fiscal memory unit I/F shift
IN
input data
CKDC, Fiscal memory unit I/F shift
OUT
output data
GND
IN
X-TAL (14.7456MHz)
IN
X-TAL (14.7456MHz)
GND
OUT
System clock (7.3728MHz)
OUT
E clock (NU)
OUT
Address strobe
OUT
Read
OUT
Write
OUT
Nu
OUT
Refresh cycle (NU)
+5V
IN
+5V (MODE 3)
IN
+5V (MODE 3)
IN
GND (MODE 3)
IN
+5V (Nu)