PROCEDURE
LETTER
YLW
4
HOOD FAN
CAPACITOR
SUB
5
102 Ω
RED
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
TEST PROCEDURES
COMPONENT TEST
BLU
1
MAIN
60 Ω
17
BLU (1)
AND
BLK (2)
AND
BLU (1)
AND
RED(5)
AND
120 v
RED(5)
AND
60 Hz
YLW(4)
AND
2
BLK
6-PIN CONNECTOR
OF HOOD FAN MOTOR
Resistance between;
YLW (4) =
0
(Shorted)
YLW (4) = 60
BLK (2) = 60
BLU (1) = 162
BLK (2) = 102
RED (5) = 162
BLU BLK
1
2
4
5
YLW RED
R-1405