Connection tothecontrol signal t erminal (continued)
Requesting
projector
status
(1) Send the request code '20H' + 'yyH'
from the computer
to the projector.
(2) The projector
returns the response
code ' 1xH' + 'yyH'
+data to the computer.
Changing
the projector
settings
(1) Send the setting code '3xH' + 'yyH'
+data from the computer
to the projector.
(2) The projector
changes the setting based on the above setting code.
(3) The projector
returns the response
code ' 1xH' + 'yyH'
+data to the computer.
( Caution ) The response
data in (3) above need not match the setting data in (1).
For example,
when the projector
cannot
set the setting data in (1), the projector
may set the/
closest
value. That value will be used as the response
data in (3). Or else the projector
wilt]
return the error code '0xH' + 'yyH'
+data.
J
Using
the projector
default
settigns
(1) The computer
sends the default setting code '40H' + 'yyH'
to the projector.
(2) The projector
changes the specified
setting to the default value.
(3) The projector
returns the default value with the response
code ' 1xH' + 'yyH'
-data.
When a command
sent by the projector
cannot
be understood
by the computer
(1) The computer
sends the command
code '3xH',
'4xH'
or '4xH' + 'yyH' +data to the projector.
(2) When
the command
sent by the projector
cannot
be understood,
the error
command
'0OH' + 'yyH'
is
returned by the computer.
When data sent by the projector
cannot
be understood
(1) The computer
sends the command
code '3xH',
'4xH'
or '4xH' + 'yyH'
+data to the projector.
(2) When the command
sent by the projector
cannot be understood,
the the error code '0xH'
+'yyH'
+data is
returned.
When the data length is greater than indicated by the data length code, the projector wilt ignore the excess data code.
Conversely,
when the data length
is shorter than indicated
by the data length code, an error code will be
retumed
to the projector.
When
a frame
error occurs
Repeats
10 times per second until there is some sort of response
to the error code 70H + 70H.
When the interval
between
bytes in one command
is 500ms or greater
When a command
or data is not sent within 500ms after the command
code '2xH',
'3xH'
or '4xH'
is sent by
the computer,
the error command
'70H'
+'70H'
will be returned
as soon as the 500ms elapses.
After this, if
there is no response
within 1 sec, a frame error will occur.
(Caution)
• Operation
cannot be guaranteed
when the projector
receives
an undefined
command
or data.
• Provide an interval of at least 40ms between the response
code and any other code.