Dell PowerEdge 2600 Service Manual page 14

Hide thumbs Also See for PowerEdge 2600:
Table of Contents

Advertisement

Memory double word logic failure at
address, read value expecting value
Memory high address line failure at
start address to end address
Memory high data line failure at start
address to end address
Memory odd/even logic failure at start
address to end address
Memory parity failure at start address
to end address
Memory parity error at address
Memory write/read failure at address,
read value expecting value
No boot device available
No boot sector on hard- disk
No PXE-capable device available
No timer tick interrupt
Not a boot diskette
PCI BIOS failed to install
Plug & Play Configuration Error Embedded
xxx
Plug & Play Configuration Error PCI_n
Primary backplane is not present
Processor n internal error
Processor bus parity error
Processor in socket 1 not installed!
SCSI cable not present on connector
SCSIA of the primary backplane
Shutdown failure
System backplane error
System halted! Must power down
Time-of-day clock stopped
Time-of-day not set - please run SETUP
program
Timer chip counter 2 failed
Unsupported CPU combination
Unsupported CPU stepping detected
Unsupported DIMM detected in the RAID
DIMM slot!
Unsupported RAID key detected!
Utility partition not available
The VRM for the processor in socket n is
not installed.
Warning: Detected mode change from RAID
to SCSI B of the embedded RAID
Faulty or missing CD/diskette
drive subsystem, hard drive, or
hard-drive subsystem.
No operating system on hard
drive.
<F12> pressed during POST and
no PXE devices are detected.
Faulty system board.
No operating system on diskette.
Loose cables to expansion card
(s); faulty or improperly installed
expansion card.
Error encountered in initializing
PCI device; faulty system board.
Error encountered in initializing
PCI adapter.
Faulty or improperly installed
SCSI backplane board.
Faulty microprocessor; faulty
system board.
No microprocessor installed in
primary microprocessor socket.
SCSI cable is loose, improperly
connected, or faulty.
Shutdown test failure.
Faulty or improperly installed
SCSI backplane board.
Wrong password entered too
many times.
Faulty battery.
Incorrect Time or Date settings;
faulty system battery.
Faulty system board.
Microprocessor(s) is not
supported by the system.
RAID memory module is not
supported by the system.
RAID hardware key is not
supported by the system.
<F10> was pressed during POST,
but no utility partition exists on
the boot hard drive.
Specified microprocessor VRM is
faulty, unsupported, improperly
installed, or missing.
Type of controller has changed
since previous system boot.
Check the boot device configuration settings in the System Setup program
for Integrated Devices (see
"Using the System Setup
were disabled, enable them and reboot. Use a bootable diskette, CD, or
hard drive. If booting from a SCSI controller, ensure that the controller is
properly connected. If the problem persists, replace the faulty drive(s) (see
"CD/Diskette
Drive" and
"Hard
Drives"). If the problem still persists, replace
the system board (see
"System
Board").
Check the hard-drive configuration settings in the System Setup program
(see
"Using the System Setup
Program").
Check the configuration settings in the System Setup program for the NICs
(see
"Using the System Setup
Program").
Replace the system board (see
"System
Use a bootable diskette.
Ensure that cables to expansion cards are properly connected. Ensure that
the expansion cards are properly installed. If the problem persists, replace
the faulty expansion card(s) (see
Install the NVRAM_CLR jumper and reboot the system (see
jumper location). If the problem persists, ensure that the expansion cards
are properly installed. If the problem still persists, replace the faulty
expansion card(s) (see
"Expansion
update the BIOS firmware. Download the latest firmware from the
Dell Support website at support.dell.com.
Ensure that the SCSI backplane board is properly installed. If the problem
persists, replace the backplane board (see
Ensure that the microprocessors are properly installed. If the problem
persists, replace the faulty microprocessor(s) (see "Microprocessors"). If
the problem persists, replace the system board (see
Install a microprocessor in the primary microprocessor socket. Also, ensure
that a VRM for processor 1 is installed (see "Microprocessors").
Ensure that the SCSI cables are properly installed. If problem persists, add
or replace the cables.
Ensure that the memory modules are properly installed. If the problem
persists, replace the faulty memory module(s) (see
Ensure that the SCSI backplane board is properly installed. If the problem
persists, replace the backplane board (see
Information only.
Ensure that the system battery is properly installed. If the problem
persists, replace the battery (see
Check the Time and Date settings (see
Program"). If the problem persists, replace the system battery (see
"System
Battery").
Replace the system board (see
"System
Update the BIOS firmware. Download the latest firmware from the Dell
Support website at support.dell.com. If the problem persists, install a
supported microprocessor combination (see "Microprocessors").
Install a correct version of the RAID memory module (see
Integrated RAID
Controller").
Install the RAID hardware key for your specific system (see
Integrated RAID
Controller").
Create a utility partition on the boot hard drive (see "Using the Dell
OpenManage Server Assistant CD" in your User's Guide).
A VRM must be installed for each installed microprocessor. Install a VRM for
the specified microprocessor or remove the VRM for the specified
microprocessor if that microprocessor is not installed (see
"Microprocessors"). To identify the microprocessors and VRMs, see
Figure 5-2.
Back up information on the hard drives before changing the type of
controller used with the drives.
Program"). If they
Board").
"Expansion
Cards").
Figure 5-2
Cards"). If the problem still persists,
"SCSI Backplane
Board").
"System
Board").
"Memory
Modules").
"SCSI Backplane
Board").
"System
Battery").
"Using the System Setup
Board").
"Activating the
"Activating the
for

Advertisement

Table of Contents
loading

Table of Contents