Connecting to the High Speed Dome

Cable Connection

HVBCPU

Address the Dome

Rev 1.0
The Orbiter, RapidDome, or HD6 domes connect to the system via an HVBPIT44 Protocol
Interface Translator (PIT). This device converts the native protocol of VideoBloX to the
protocol of the connected dome.
1.
Using the 9-pin Male to 9-Pin Male (pin to pin) connect the Slave Channel of the PIT to
the RS422 Master port on the VideoBloX CPU module. This is the fourth connector
from the left port when viewing the chassis from behind.
2.
Using the RS422 cable with 9-Pin male connector on one end and fly leads" on Pins 1
and 2, connect Pin #1 (TXD -) to the Data (-) on the Dome. Connect Pin #2 (TXD +) to
the Data (+) on the Dome.
Figure 5
Connecting an HVBPIT44 and High Speed Dome
Pin 1 (TXD-) to Data -
Pin 2 (TXD+) to Data+
RS422
Master
HVBPIT44
2 3 4 56 8
7
1
RS422
Slave
DB9 Male to DB9 Male
RS422
Master
1.
Set the Dome to address #1 (see Manual for Dome )
2.
Set the Dome for VCL or Maxpro mode protocol (see Manual for Dome)