Installation Instructions
Please Note:
This product should only be installed by a qualifi ed
electrician or competent heating installer, and should be
in accordance with the current edition of the IEEE wiring
regulations.
Product specifi cation
Specifi cation
Power supply
Switching action
Switch rating
Battery back-up
Setting/Running Accuracy
Dimensions, mm (W, H, D)
Design standard
Control Pollution Situation
Rated Impulse Voltage
Ball Pressure Test
Installation
Remove wallplate from unit by unscrewing the two screws
on the bottom edge of the unit.
From the top left hand corner of the wallplate, there must
be clearances of at least 140 mm to the right, 15mm to the
left, 30mm above and 100mm below in order to mount
the plug-on module.
230V Model
230 Vac, ±15%,
50/60 Hz
1 x SPDT voltage free, Type 1B
24 - 230 Vac, 3(1)A
24 hours minimum
±1 minute
135 x 88 x 32
EN 60730-2-7
Degree 2
2.5kV
75°C
24V Model
24Vac, ±15%,
50/60Hz
3
Need help?
Do you have a question about the TS715 Si and is the answer not in the manual?
Questions and answers