5. A
PPENDIX
General Troubleshooting
If you still have a problem after trying the above solutions, please contact CHAUVET®
Technical Support.
MinLasers 2.0 User Manual
S
P
YMPTOM
OSSIBLE
Excessive circuit load
Breaker/Fuse
Short circuit along the power
keeps blowing
wires
No power
Device does not
Loose power cord
power up
Wrong DMX addressing
Damaged DMX cables
Product is not
Wrong polarity settings on the
responding to
controller
DMX
Loose DMX cables
Faulty DMX interface
Faulty Main PCB
Non DMX cables
Bouncing signals
Long cable / Low level signal
Loss of signal
Too many products
Interference from AC wires
C
(
)
AUSE
S
Check total load placed on the
electrical circuit.
Check for a short in the electrical
wiring (internal and/or external).
Check for power on Mains.
Check power cord
Check Control Panel and unit
addressing
Check DMX cables
Check polarity switch settings on
the controller
Check cable connections
Replace DMX input
Replace Main PCB
Use only DMX compatible cables
Install terminator as suggested.
Install amplifier right after product
with strong signal.
Install an optically coupled DMX
splitter after unit #32.
Keep DMX cables separated from
power cables or black lights.
13