8. Repeat the operation of the Raise Priority command until the row of the
selected path is displayed in the head of the Selected Paths list and its
Priority column changes to "1".
When the Priority column changes to "1", it means the cross-subsystem
path is set as the usually used one (primary path).
9. Click OK to close the Configure Cross-subsystem Paths dialog box.
You are returned to the Volume Operation window. The settings are
displayed in blue and italics.
10. Verify the settings in the Preview dialog box.
11. Click Apply in the Volume Operation window.
The settings are applied to the local storage system and the Volume
Operation window is displayed normally. When an error occurs, an error
message is displayed. Verify the details in the Preview dialog box.

Canceling the Cross-subsystem Path Configuration

You can cancel the configuration of the cross-subsystem path using the
Configure Cross-subsystem Paths dialog box.
To cancel the cross-subsystem path configuration:
1. Start Storage Navigator, and open the Volume Operation window.
2. Make sure that Storage Navigator is in Modify mode.
3. Click the path group to which the cross-subsystem path belongs in the
Volume Operation tree.
4. Right-click the cross-subsystem path in Cross-subsystem Paths in the
Volume Operation list.
5. Click Configure Cross-subsystem Paths in the pop-up menu.
6. In the Configure Cross-subsystem Paths dialog box, right-click the cross-
subsystem path that you want to cancel the configuration in the Selected
Paths.
7. Click Delete in the pop-up menu
The configuration of the selected cross-subsystem path is canceled, and
the cross-subsystem path is deleted from the Cross-subsystem Paths.
8. Click OK to close the Configure Cross-subsystem Paths dialog box.
You are returned to the Volume Operation window. The settings are
displayed in blue and italics.
9. Verify the settings in the Preview dialog box.
10. Click Apply in the Volume Operation window.
The settings are applied to the local storage system and the Volume
Operation window is displayed normally. When an error occurs, an error
message is displayed. Verify the details in the Preview dialog box.
5-24
Hitachi Universal Storage Platform V/VM Universal Volume Manager User's Guide
Performing Universal Volume Manager Operations