Power Supply Cord Replacement - Sharp R-4A52 Service Manual

Microwave oven r-4a52; r -4,e52
Table of Contents

Advertisement

R-4A52
R-4E52
\
Tab of the door panel
Figure
C-8. Latch head removal
Figure
C-9.
Latch
head re-install
LATCH
HEAD
RE-INSTALL
1. Pick up the latch spring and catch the one ring of
the latch spring
on the tab of the door
panel as
shown
in Figure C-9.
2. Catch the other ring of the latch spring
on the tab
of the latch head.
3. Install the latch head to the holes in the door panel.
POWER
SUPPLY
CORD
REPLACEMENT
(FOR
AUSTRALIA
MODEL)
Removal
1. CARRY OUT 30 CHECKS.
2. Disconnect
the brown
wire
of the power
supply
cord from the fuse holder.
3. Remove the connector
CE-230
by cutting
the con-
nected wire leads to it.
4. Remove
the
single
(1)
screw
holding
the
green/yellow
wire of the power supply
cord to the
oven cavity.
5. Remove
the
single
(1)
screw
holding
the
cord
anchorage
to the oven cavity.
6. Remove the power supply cord from the oven.
Re-install
1. Insert
the
power
supply
cord
into
the
cord
anchorages.
2. Connect
the brown
wire of the power supply
cord
to the fuse holder.
3. Install the green/yellow
wire of the power
supply
cord to the oven cavity
with
the single
(1) screw
tightly.
4. Make sure that the blue wire and the white
wires
are stripped
for 15 mm length
as shown
in Figure
C-II.
5. Wind the conductors
of Blue and White wires each
other.
6. Insert the stripped
wire
leads into the connector
CE-230.
7. Clamp the connector
CE-230
with
the correct
tool
tightly.
Cord anchorage
I
Brown wire
\
Fuse holder
Green/Yellow wire
Figure
C-10
Power
Supply
Cord Replacement
for Australia
Model
Blue wire of power supply cord
White wire of main harness
33::
Conductors
Connector CE-230
Figure
C-II
Wiring