5. Model KN-COPP-B Operating Characteristics
When the unit is first powered up, the green
Operate LED flashes once every 30 seconds and
the digital display will show three "eights" –
indicating the alarm is in the start-up mode. The
three "eights" will remain for approximately 30
seconds. Then, the alarm will display "0" and
begin monitoring the air for CO and will contin-
ue to do so as long as it receives power.
This alarm will display a "0" if CO concentrations between 0 and 30
PPM have been detected within the last 15 seconds.
The following table illustrates the possible digital displays, describes the
audible alarm patterns, and the recommended actions to take.
Operating and Alarm Characteristics
LCD Display Shows
Alarm Sound
A steady display of
4 quick beeps,
CO concentration
5 secs. silence,
from 30-999. Red
repeating for 4
LED flashes with beeps
min.– then 4
quick beeps
every minute
Brief "888" for
4 quick beeps,
approximately 30
5 seconds
seconds
silence,
repeated once
Steady "0"
None
displayed, dot flash-
ing every 5 seconds,
Green LED flashes every 30 secs.
Three battery seg-
None
ments displayed
Two battery seg-
None
ments displayed
One battery seg-
None
ments displayed
"LB" flashes alter-
One quick beep
nately with any
every 30 seconds
number, Red LED
flashes every 30 seconds.
Battery icon displays outline of
the battery
Test/
Reset
Operate
Green Operate LED
Unit Status
Recommendation
Alarm condition.
Refer to "What to do
Dangerous
When the Alarm
concentrations of
Sounds" (inside front
CO detected
cover)
Self test when first
None – CO has not
powered up or
been detected.
after Test/Reset but-
Numbers shown for
ton is pressed
test purpose only
Normal DC
None
operation with
good batteries
(sensing no CO)
Batteries are at full
None
capacity
Batteries are at 2/3
None
capacity
Batteries are at 1/3
Replace all three AA
capacity
batteries
Remaining battery
Replace all three AA
capacity shown.
batteries immediately
Batteries need to be
replaced
5. Model KN-COPP-B Operating Characteristics
LCD Display Shows
Alarm Sound
"Err" displayed –
One quick beep
battery icon may
every 30 seconds
show any state of
battery capacity
Display is blank
Constant alarm
Number from 11-
None
999 displayed. Top
segment of battery
icon displayed
The problems listed above are under normal operating conditions. Other
"Err" conditions could exist. If you should have any questions regarding
display conditions, call our Consumer Hotline.

Peak Level Memory

When the Peak Level button is pressed and held, the display shows the
highest CO reading taken by the CO alarm since its
last reset or power up. The battery fuel gauge
changes to show only the top segment of the battery
to indicate that peak level is being displayed. In this
example 120 PPM was the maximum amount of CO
recorded since the unit was last reset.
The Peak Level display feature will display levels
between 11-999 PPM. Although the Peak Level feature will display levels
below 30 PPM, these levels will not result in an alarm no matter how
long the device is exposed to these levels. The Peak Level feature is help-
ful in identifying if you have had a CO reading since resetting the alarm.
Concentrations of CO between 1 and 30 PPM can often occur in nor-
mal, everyday conditions. Concentrations of CO below 30 PPM may be
an indication of a transient condition that may appear today and never
reappear. Some CO conditions may start out as low level leaks but could
develop into CO concentrations that may become harmful.
If this happens, the CO alarm will detect the dangerous level and alarm,
notifying you and others of the conditions. DO NOT ignore high con-
centration readings above 30 PPM or a CO alarming device that is
in alarm.
Unit Status
Recommendation
Unit is Error condi-
Replace batteries.
tion
If "Err" (or blank
display) continues,
unit has malfunc-
tioned. Replace
immediately. Unit will
Unit malfunction
not respond CO
Peak Level Memory
Refer to section
activated. Highest
below for informa-
concentration of
tion regarding Peak
CO detected is dis-
Level Memory
played
Sample Peak
Level Reading