Air Filters
[]NIT
OPERATION
HAZARD
Failure
to follow
this caution
may
result
in
property
damage.
Never
operate
your
unit
without
filters
in
place.
An
accumulation
of dust and lint on internal
parts of your unit
can
cause
loss
of efficiency
and
blower
motor
and/or
compressor
damage.
The
air filter(s)
should
be checked
every
3 or 4 weeks
and
changed
or cleaned
whenever
it becomes
dirty.
Dirty
filters
produce
excessive
stress
on the blower
motor
and can cause
the
motor to overheat
and shut down.
This unit must
have air filters in place before
it can be operated.
These filters can be located
in one of at least two places.
In many
applications,
the
installer
will
provide
return
air
filter
grilles
mounted
on the wall or ceiling
of the conditioned
structure.
In the
instance
of filter grilles, the filters can simply
be removed
from the
grille and replaced.
The other
typical
application
is an accessory
filter
rack installed
inside the unit itself. The following
information
is given to assist in
changing
filters used in these internal
filter racks.
Table 1 indicates
the correct
indoor
filter size for your unit. Refer
to Fig.
2
to access filters installed
in the accessory
filter rack. If
using an Accessory
Filter Rack, refer to the Installation
Instructions
provided
with it for correct
filter sizes and quantities.
Table
1 - Indoor
Air Filter
Data
Unit Size
Filter Size
24040
20x20x1 (508x508x25 mm)
24060, 30
20x24x1 (508x610x25 mm)
66 - 42
24x60x1 (610x762x25 mm)
48 - 60
24x66x1 (610x914x25 mm)