Maytag MGR5710 User Manual page 21

Rs
Hide thumbs Also See for MGR5710:
Table of Contents

Advertisement

Oven Bottom
s. Reverse procedure to reinstall. If gas line has been
disconnected, check for gas leaks after reconnection
Protect oven bottom against spillovers, especially acid or
NOTE: A qualified servicer should disconnect and re-
sugary spills, as they may discolor the porcelain enamel. Use
connect the gas supply.
the correct pan size to avoid spillovers and boilovers. Do not
6. To prevent range from accidentally tipping, range must
place aluminum foil directly on the oven bottom.
be secured to the floor by sliding rear leveling leg into the
The oven bottom may be
t_ _
anti-tip bracket.
removed for easier clean-
ing.
To remove: When cool, ((
Proportional
Valve Adjustment
remove the oven racks. _
2
for Surface Burners
Slide the two catches, lo-
cated at each rear corner
The LOW setting should pro-
oftheovenbottom,
to- _
_
duceastableflamewhentum-
wardthefrontoftheoven,
t3
ing the knob from HIGH to
LOW. The flame should be 1/8
Lift the rear edge of the
inch or lower and must be stable
oven bottom slightly, then
on all ports on LOW setting.
slide it back until the front edge of the oven bottom clears the
oven front frame. Remove oven bottom from oven.
To adjust: Operate burner on
HIGH for about five minutes to
To replace: Fit the front edge of the oven bottom into the
preheat burner cap. Turn knob back to LOW; remove knob,
oven front frame. Lower the rear of the oven bottom and slide
and insert a small screwdriver into the center of the valve
the two catches back to lock the oven bottom in place,
stem. Adjust the flame size by turning adjustment screw in
eithcr dircction, while holding the stem.
How to Remove Range
Flame must be of sufficient size to be stable on all burner
for Cleaning and Servicing
ports. If flame adjustment is needed, adjust ONLY on the
LOW setting. Never adjust flame size on a higher setting.
Follow these procedures to remove appliance for cleaning or
NOTE: All gas adjustments should be done by a quali-
servicing:
fled servicer only.
1. Shut off gas supply to appliance.
2. Disconnect electrical supply to appliance, if equipped.
3. Disconnect gas supply tubing to appliance.
4. Slide range forward to disengage range from the anti-tip
bracket. (See Installation Instructions for location of
bracket.)