Product Identification; Unpacking; Fuels; Ventilation - Desa 125,000 Btu/Hr Owner's Manual

Portable forced air heaters 125,000 and 170,000 btu/hr thermostat 100,000 140,000 and 200,000 btu/hr variable output with thermostat
Table of Contents

Advertisement

PRODUCT IDENTIFICATION

Upper Shell
Hot Air
Outlet
Lower
Shell
Fuel Cap/
Gauge
Shroud
ON/OFF
Switch
Control Cover
Ignition Control Assembly
(On Inside of Control Cover)
Figure 1 - Variable Output With Thermostat Model
Upper Shell
Hot Air
Outlet
Lower
Shell
Fuel Cap/
Gauge
Shroud
ON/OFF
Switch
Control Cover
Ignition Control Assembly
(On Inside of Control Cover)
Figure 2 - Thermostat Model
108481
Handle
Heat Output Knob
Thermostat Knob
Extension
Fuel
Cord Wrap
Rear
Tank
Panel
Handle
Thermostat Knob
Extension
Fuel
Cord Wrap
Rear
Tank
Panel
For more information, visit www.desatech.com
For more information, visit www.desatech.com

UNPACKING

1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check items for any shipping damage. If heater is damaged,
promptly inform dealer where you bought heater.
Fan

FUELS

Guard
WARNING: Use only kerosene, #1/#2 diesel/fuel
oil, JET A or JP-8 fuels to avoid risk of fire or explo-
sion. Never use gasoline, oil drained from crank-
cases, naphtha, paint thinners, alcohol or other highly
flammable fuels.
Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels.
Heavier fuels such as No. 2 fuel oil or No. 2 diesel fuel may also be
used but will result in:
• noticeable odor
• additional fuel filter maintenance
• the need for nontoxic, anti-icer additives in very cold weather
Do not use fuels heavier than No. 2 grade or heavy oils such as oil
drained from crankcases. These heavy oils will not ignite properly
and will contaminate the heater.
IMPORTANT: Use a KEROSENE ONLY (blue) or DIESEL ONLY
(yellow) storage container. Be sure storage container is clean. Foreign
matter such as rust, dirt, or water will cause the ignition control
Fan
assembly to shut down heater. Foreign matter may also require
Guard
heater's fuel system to be frequently cleaned.

VENTILATION

WARNING: Provide a fresh air opening of at least
three square feet (2,800 square cm) for each 100,000
BTU/HR rating. Provide extra fresh air if more heaters
are being used. The minimum ventilation require-
ments must be followed to avoid risks associated
with carbon monoxide poisoning. Make certain these
requirements are met prior to operating heater.
Example: A 58.6kw (200,000 Btu/Hr) heater requires one of the
following:
• a two-car garage door [4.88 meter (16 feet) opening] raised
12.7 cm (5 inches)
• a single-car garage door [2.74 meter (9 feet) opening] raised
20.3 cm (8 inches)
• two, 76.2 cm (30 inch) windows raised 38.1 cm (15 inches)
PRODUCT IDENTIFICATION
UNPACKING
FUELS
VENTILATION
3 3