Introduction; Basic Description; Basic Tools Needed; Basic Materials Needed - Williams 4007332 Owner's Manual

Counterflow direct-vent gas wall furnaces
Hide thumbs Also See for 4007332:
Table of Contents

Advertisement

Introduction

Dear Customer,
To set up our furnace assembly procedures, several hundred quality assurance, safety audit and design performance tests have been
conducted according to the standards provided by the American National Standards Institute, the Department of Energy and our
certification agency - the American Gas Association Laboratories.
This was done to assure you of receiving the best value and most reliable appliance of its type available today. We are confident that
your Williams furnace can provide you years of low cost, efficient, heating comfort.
Thank you for purchasing a Williams furnace.
Please read our instructions before you install and use your furnace. This will help you obtain the full value from this furnace. It could
help you avoid needless service costs, if the answer to the problem in found within this instruction manual.

Basic Description

The direct vent wall furnace is shipped ready to install against
an exterior wall not exceeding 9" in thickness. Furnace may
also be recessed up to 10" in a wall with studs spaced 16"
center-to-center.
Always consult your local heating or plumbing inspector,
building
department
or
regulations, codes or ordinances which apply to the installation
of a direct vent furnace.
Air is drawn in at the top by the fan and discharged through a
grille near the floor. A two-speed fan is used with models
5507332, 6007732, 5507331, and 6007731. A single speed fan
is used on all other models. The furnace contains a multi-slot
burner (two on models 5507332, 6007732, 5507331, and
6007731) and burns either natural or L.P.G (liquefied
petroleum gas), depending on the model you have purchased.
Tools Needed
Hand drill or properly grounded electric drill
Expansion bit 1/2" to 1-5/8" or 1/2'' and 1-1/2" blade bits
1/8" and 3/16" drill bit (metal)
6 ft. folding rule or tape measure
Screwdrivers (med. blade) and (Phillips Head)
Pliers (wire cutting)
Hammers
1/8" allen wrench
Materials
Pipe and fittings to make connections to furnace (See page 18).
Caulking compound-silicone rubber with a temperature rating of
500
F.
DO NOT use caulking compound advertised as paintable or for
bath tub use as most contain fillers and will not withstand high
temperatures.
Pipe Joint Compound resistant to L.P. Gas.
Helpful Installation Information
The following booklets will help you in making the installation:
ANSI/NFPA 70-1990 or current edition "National Electrical Code". In Canada: CSA C22.1 Canadian Electrical Code.
American National Standard NFPAS4/ANSI Z223.1 1988 or current edition "National Fuel Gas Code".
Obtained from: American National Standards Institute, Inc., 1430 Broadway, New York, N Y 10018.
In Canada: CAN/CGA B149.
A Word from the Manufacturer
gas
utility
company
regarding
Sincerely,
Employees of Williams Furnace Company
The sealed combustion system draws combustion air directly from
outdoors into the combustion chamber and combustion gases are
discharged directly to the outdoors through tubes mounted to the
rear of the furnace.
The furnace heat exchanger is built of heavy gauge steel treated
for corrosion resistance. The fan at the top, forces air down along
the front, back and sides of the heat exchanger where it is
discharged into the room. The furnace cabinet is also constructed
of heavy gauge steel and has a powder-coat paint finish.
The furnace controls are located behind an access door on the
lower front of the furnace. All models are equipped with American
Gas Association listed gas valves and pilots.
Models 4007332, 4007331, 5507332, and 5507331 are equipped
with an electronic ignition automatic pilot relight system.
Stud locator or small finishing nails.
Tin snips
8" and 12" adjustable wrenches
Keyhole or sabre saw
Hack saw
2 - 10" or 12" pipe wrenches
Gloves and safety glasses
Electrical wiring supplied as needed (see page 19). Minimum wire
size is #14 gauge copper.
3/4" Quarter Round or other wood trim molding approx.
16' long or Trim Strip Kit 4701.
2" x 4" x (length as required) Spacer Block (See Page 9).
1" x 1" wood strips if Optional Side Outlet Grille Kit 6701 is
used.
Introduction – 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

550733260077324007732400733140077315507331 ... Show all

Table of Contents