Kenmore 29-Inch Wide GAS DRYERS Owner's Manual And Installation Instructions page 13

Hide thumbs Also See for 29-Inch Wide GAS DRYERS:
Table of Contents

Advertisement

Standard exhaust installation with rigid
metal or flexible metal vent
Alternate installations for close
clearances
Venting systems come in many varieties.
Select the type best for your installation.
Two dose-clearance
installations are
shown. Refer to the manufacturer's
instructions.
-..L .....
1. Over-The-Top
installation (also
available with one offset elbow)
2. Periscope
installation
NOTE: The following kits for close clearance altemate-
installations
are available
for purchase.
Please see the
service number located on the back page of this
manual 1oorde_
• Over-The_Top Installation:
Part Number 26-49900
• Periscope
Installation
(For use with dryer vent to
wall vent mismatch):
Part Number 26-49901 - Less than 5 in. (12.7 cm)
mismatch
Part Number 26-49908 - 5 in. (12.7 cm) to 18 in.
(45.72 cm) mismatch
Part Number 26-49904 - 18 in. (45.72 cm) to 29 in.
(73.65 cm) mismatch
Part Number 26-49905 - 29 in. (73.56 cm) to 50 in.
(127 cm) mismatch
Special provisions for mobile home
installations
The exhaust vent must be securely fas-
tened to a noncombustible
portion of the
mobile home structure. Do not use
screws or other fastening devices that
extend into the interior of the vent to
secure vent.
Terminate the exhaust vent outside.
The exhaust vent must not terminate
beneath the mobile home and must not
be connected to any other duct, vent or
chimney.
Determine Vent Length
t.
Select the route that will provide the
straightest and most direct path out-
doors. Plan the installation to use the
fewest number of elbows and turns.
When using elbows or making turns,
allow as much room as possible.
Bend vent gradually to avoid kinking.
Avoid 90 ° turns.
better
good
2. Determine vent length
The maximum length of the exhaust
system depends upon:
• The type of vent (rigid metal or flexi-
ble metal).
• The number of elbows used.
• Type of hood
Recommended
hood styles are shown
here.
1
I 4"
J
(1&2 cm)
1. Louvorod
hood style
2. Box hood style
13

Hide quick links:

Advertisement

Table of Contents
loading