Heat & Glo EVEREST EVEREST Installer's Manual page 12

Heat & glo lifestyle indoor fireplace user manual
Table of Contents

Advertisement

V
1' MIN. (305mm)
2' MIN. (610mm)
4' MIN. (1.22m)
V+H= 40' MAX. (12.4MM) H = 20' MAX. (6.2m)
o
NOTE: If a 90
elbow is first attached to the unit, the
maximum horizontal run is 3-feet (914mm).
NOTE: For corner installations: A 6-inch (152mm) section of straight
pipe may need to be attached to the fireplace before a 90
to allow the vent pipe to clear the top standoffs.
Figure 7.
Venting with One 90° Elbow
VENTING WITH ONE (1) 90° ELBOW
H
10' MAX. (3.1m)
15' MAX. (4.65m)
20' MAX. (6.2m)
H
Heat & Glo • Everest • 750-900 Rev. L • 1/06
H
o
elbow,
V
V
12