D. Wiring Intermittent Pilot Ignition (IPI) with 3-Wire Assembly
FAN
REM/AUX
TRANS
THERMOSTAT
WIRE ASSEMBLY
Figure 9.
If your fireplace looks like Figure 9 remove the 3-wire off the jumper wire by unplugging the spade from jumper wire. Install the
jumper wire on the wire as shown see Figure 10. Then install one of the leads from the remote receiver onto the valve and other
wire into the lead on the jumper wire.
FAN
REM/AUX
TRANS
BATTERY PACK
Figure 10.
TRANSFORMER
3 VAC
PLUG IN
BATTERY PACK
ON/OFF
SWITCH
REMOTE
RECEIVER
TRANSFORMER
3 VAC
PLUG IN
IGNITION
MODULE 3 VAC
I
S
GROUND TO
FIREPLACE CHASSIS
JUMPER WIRE
(TO BROWN)
I
S
IGNITION
MODULE
3 VAC
GROUND TO
FIREPLACE CHASSIS
JUMPER
WIRE
(TO BROWN)
6
INTERMITTENT
PILOT IGNITOR
WHITE
ORANGE
VALVE
INTERMITTENT
PILOT
IGNITOR
WHITE
ORANGE
VALVE

Hide quick links: