Download Print this page

American Standard Hamilton 7024 Installation Instructions Manual page 4

Centerset lavatory faucet with everclean finish & speed connect drain

Advertisement

9
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks.
if necessary.
10
SERVICE
To change direction of handle:
Turn valve to OFF position
Turn INDEX BUTTON (1) "counter-clockwise" and remove.
Remove HANDLE SCREW (2).
Pull off HANDLE (3). Pull off ADAPTER (4).
Remove SPRING CLIP (5). Lift STOP WASHER (6),
turn 90˚ and replace. Replace SPRING CLIP (5).
Replace ADAPTER (4).
Install HANDLE (3) in correct position by adjusting
male teeth on ADAPTER (4) to female teeth in
HANDLE ASSEMBLY (1).
Install HANDLE SCREW (2) and tighten. Thread
INDEX BUTTON (1) clockwise.
11
EverClean™ Finish
Care Instructions
American Standard's EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean
water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
1
Tighten
90˚
5
4
5
WASTE
OUTLET
2
1
2
6
4
4
1
3
2
"P" TRAP
3
M 9 6 8 8 6 7 R e v. 1 . 1

Advertisement

loading