Download Print this page

HP ProLiant ML570 Quickspecs page 19

Generation 2
Hide thumbs Also See for ProLiant ML570:

Advertisement

QuickSpecs
Options
Storage Controllers
Storage Controllers
Storage Controllers
Storage Controllers
Communications
Communications
Communications
Communications
Redundant Options
Redundant Options
Redundant Options
Redundant Options
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
512MB DDR BBWC Upgrade
Smart Array 641 Controller
Smart Array 642 Controller
256-MB Battery-Back Cache Module
NOTE: This 256-MB Battery-Backed Cache Module supports the Smart Array 5300
NOTE:
NOTE:
NOTE:
series controllers, HP StorageWorks Modular Smart Array 1000 and the HP
StorageWorks Modular Smart Array 500.
128MB Battery-Backed Cache Enabler
NOTE:
NOTE:
NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array
NOTE:
642 Controller.
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
Ultra320 Expansion Module for SA-6402
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical
NOTE:
NOTE:
NOTE:
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols
supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported,
Cache, RAID support, and additional information:
http://h18000.www1.hp.com/products/quickspecs/11587_na/11587_na.HTML
(Smart Array 6400 Series)
http://h18000.www1.hp.com/products/quickspecs/12067_na/12067_na.HTML
(Smart Array 641)
http://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.HTML
(Smart Array 642)
http://h18000.www1.hp.com/products/quickspecs/10429_na/10429_na.HTML
(SCSI Adapter)
http://h18000.www1.hp.com/products/quickspecs/11555_na/11555_na.HTML
(U320 Adapter)
HP NC310F PCI-X 1000SX Gigabit Server Adapter
HP NC320T PCI Express 1000T Gigabit Server Adapter
HP NC1020 PCI 1000T Gigabit Server Adapter
HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter
HP NC7771 PCI-X 1000T Gigabit Server Adapter
NOTE: Any network adapter (NIC), except the NC1020, on the option list can be
NOTE:
NOTE:
NOTE:
used for redundancy with the embedded NC7782 NIC. When teaming with other
NICs or with the embedded NIC, the lack of Jumbo Frames and LSO features on the
NC1020 will cause high end NICs to have those features disabled. (e.g.
incompatibility issues with the other option NICs for that platform).
Hot-plug Redundant Fan Kit
NOTE: Included in Rack Optimized models.
NOTE:
NOTE:
NOTE:
Hot Plug Redundant Power Supply
NOTE: Included in Rack Optimized models.
NOTE
NOTE
NOTE
DA - 11421
North America — Version 53 — December 16, 2005
HP ProLiant ML570 Generation 2 (G2)
HP ProLiant ML570 Generation 2 (G2)
HP ProLiant ML570 Generation 2 (G2)
HP ProLiant ML570 Generation 2 (G2)
273915-B21
273914-B21
372538-B21
291966-B21
291967-B21
254786-B21
351580-B21
268351-B21
284688-B21
273911-B21
368169-B21
367047-B21
353377-B21
313881-B21
290563-B21
128284-B21
236845-001
Page 19

Advertisement

loading

This manual is also suitable for:

Proliant ml570 g2Proliant ml570 generation 2