8. MIDI Control Settings
62
ELS-01/01C/01X Version 1.7 New Functions
3 INTERNAL/EXTERNAL
Switches control over the displayed items between the Electone (INTERNAL) or the
connected device (EXTERNAL).
3 -1 LEAD 1
Determines Internal or External control of the Lead Voices.
INT. (Internal): Lead Voice 1 is played from the Upper keyboard of the
Electone. (If the To Lower function is on, it is played from Lower keyboard.)
EXT. (External): The Lead Voice 1 is played from the connected instrument via
MIDI channel 4.
3 -2 SYNC.
To synchronize playback with an external MIDI device, you can use either the
instrument's internal clock (int.) or MIDI clock signals from the external device
(ext.).
INT. (Internal): The instrument uses its own internal clock.
EXT. (External): The instrument uses MIDI clock signals from the external
device (MIDI).
3 -3 EXPRESSION
Determines the control of the expression pedal functions. Ordinarily, this
control is set to AUTO.
AUTO: Internal and External is automatically switched.
INT. (Internal): You can manually control the expression pedal even during
M.D.R. playback.
EXT. (External): While playing the M.D.R. or receiving MIDI messages, the
expression pedal is invalid. (The volume is controlled by the recorded data in a
SmartMedia card or received MIDI data.)