A. Valve Access and Service
•
The gas valve can be accessed behind the cement
refractory panel on the right side of the fi replace.
•
Lift doors out and set aside. There is a washer under each
door. Be careful not to lose the washers.
Figure 11.1 Lift Out Doors
•
Remove logs if access is necessary after installation is
complete. See Section 9.C. Remove logs in reverse order
of set up.
•
Remove grate if access is necessary after installation is
complete. (Refer to Section 9.B.)
•
Remove two screws on side of pilot shield and remove
shield.
Figure 11.2 Remove Pilot Shield
•
Use a phillips screwdriver to remove the two screws
securing the refractory retaining strip. Remove the
refractory side panel and set aside.
Figure 11.3 Loosen Refractory Retaining Strip
WASHER
WASHER
Heat & Glo Lifestyle Collection • Dakota 42-CE • 4036-915 Rev I • 11/07
•
Remove the inside valve access panel by lifting it up and
out.
Figure 11.4 Remove Valve Access Panel
•
Use a phillips screwdriver to remove the exterior valve
access panel (remove four screws).
Figure 11.5 Remove Exterior Valve Access Panel
•
Loosen lower pressure tap screw before attaching
manometer. Start up the fi replace to verify the pressure
and adjust as necessary. Reverse these steps to
reassemble before log positioning.
Note: Pressure tap screws must be re-tightened.
Figure 11.6 Connect Manometer
21