11
11
Maintaining and Servicing the Fireplace
Although the frequency of fi replace servicing and maintenance will depend on use and the type of installation, a qualifi ed
service technician should perform an fi replace check-up at the beginning of each heating season.
Debris from any outside source and/or soot must be removed from the fi eplace. Allow logs to cool, remove if necessary,
vacuum and replace in accordance with instructions on pages 13-15.
WARNING
Risk of injury or property damage
Before servicing:
•
Turn off gas.
•
Disable remote control, if one is present.
•
Ensure fi replace is completely cooled.
After Servicing:
•
Replace any screen or barrier that was removed.
•
Reseal and reinstall any venting removed for
servicing.
WARNING
Annual inspection by qualified technician
recommended.
Check:
•
Condition of doors, surrounds and fronts.
•
Condition of glass, glass assembly.
•
Obstructions of combustion and ventilation
air.
•
Condition of logs.
•
Condition of fi rebox.
•
Burner ignition and operation.
•
Burner air shutter adjustment.
•
Gas connections and fi ttings.
Clean:
•
Glass.
•
A i r p a s s a g e w a y s , g r i l l e s , c o n t r o l
compartment.
•
Burner, burner ports.
Risk of:
•
Fire
•
Delayed ignition or explosion
•
Exposure to combustion fumes
•
Odors
20
Heat & Glo Lifestyle Collection • Dakota 42-CE • 4036-915 Rev I • 1/07
CAUTION
Handle glass assembly with care.
Note: Clean glass after initial 3-4 hours
operation. Longer operation without
cleaning glass may cause a permanent
white fi lm on glass.
When cleaning glass door:
•
Avoid striking, scratching or slamming
doors.
•
Do NOT use abrasive cleaners.
•
Use a hard water deposit glass cleaner on
white fi lm.
•
Do NOT clean glass when it is hot.
•
Turn off fi replace after 3-4 hours of operation
and ALLOW TO COOL.
•
Remove and clean glass assembly.
•
Replace glass assembly and operate
fi replace for an additional 12 hours.