Clearances - Heatilator ST42A Owner's Manual

See-through woodburning fireplace
Table of Contents

Advertisement

B. Clearances
10
WARNING
Fire Risk
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause fi re.
Storm Collar
Roof Flashing
2 in. min.
(51 mm)
(attic)
2 in. (51 mm) min.
Firestop Spacer
2 in. (51 mm) min.
0 in.
to floor
Figure 3.2
Clearances to Combustible Materials
Heatilator • ST42A • 35038 Rev G • 02/05
2 in. (51 mm) min.
Attic
Insulation
Shield
Firestop Spacer
(ceiling)
2 in. (51 mm) min.
2 in. (51 mm) min.
Offset/Return with
hanger straps
(ceiling)
2 in. (51 mm) min.
Must have 2 in. (51 mm)
minimum clearance
to header
0 in. to level
of standoffs
1/2 in. (13 mm) to side of appliance