C. Sidewalls/Surrounds
Adjacent combustible side walls must be located a minimum of 12 in. (305 mm) from the fi replace opening. See Figure 3.3.
If you are using a decorative surround constructed of combustible material, it must be located within the shaded area de-
fi ned in Figure 3.3. Short stub walls are also acceptable if they are contained within the shaded area.
D. Frame the Fireplace
Figure 3.4 shows a typical framing (using 2 x 4 lumber) of the fi replace, assuming combustible materials are used. All re-
quired clearances to combustibles around the fi replace must be adhered to. See Figure 3.2. Any framing across the top of
the fi replace must be above the level of the top standoffs.
2 in. (51 mm)
min. air
clearance
to the
enclosure.
41-1/2 in.
(1055 mm)
23 in.
(584 mm)
Figure 3.4
Framing the Fireplace
14-3/8 in.
Flush
(365 mm)
Front
50 deg.
12 in.
(305 mm)
Model #
Fireplace Opening
in.
EM-415
EM-415H
mm
Figure 3.3
Sidewalls and Surrounds
A
Heat & Glo • EM-415/EM-415H • 31317 Rev Q • 10/06
4 in.
(102 mm)
Brick
9-3/4 in.
Front
(248 mm)
A
B
39 deg.
12 in.
(305 mm)
A
B
Outside Dimensions
36
42
914
1067
Note: Fireplace
header cannot be
positioned until
after the fireplace
assembly is in place.
41-1/2 in. (1055 mm)
header height.
Use only noncombustible
material below the top
of the front standoffs.
Model #
in.
EM-415
EM-415H
mm
A
43
1092
11