Locating & Cutting Floor Openings - Nordyne Air Conditioner / Heat Pump Air Handler Owner's Manual & Installation Instructions

E3 series (air conditioner / heat pump air handler) downflow, upflow electric furnaces
Table of Contents

Advertisement

REAR WALL OF CLOSET OR ALCOVE
1 3/4" MIN.
OPTIONAL
REFRIGERANT LINE
10"
3 1/8" X 5 3/4"
STANDARD DUCT CONNECTOR
REAR WALL OF CLOSET OR ALCOVE
OPTIONAL
REFRIGERANT LINE
10"
3 1/8" X 5 3/4"
ROUND DUCT CONNECTOR
Figure 5. Cut-Out Dimensions for Upfl ow
Furnaces
Locating & Cutting Floor Openings
Floor cut-outs must be carefully located to avoid
misalignment of the furnace and air duct. Standard and
round cutouts for upfl ow furnaces are shown in Figure
5. Figure 6 displays the cutouts for downfl ow furnaces.
1. Measure and mark the centerline of the cutout. Provide
minimum clearances at rear and right side walls of
closet or alcove for installation of furnace and wiring.
2. Using the centerline as a starting point, draw the rest
of the duct cut-out to the dimensions shown in Figures
5 or 6. NOTE: Additional provisions may be necessary
for optional air conditioning or heat pump if refrigerant
lines are installed elsewhere than at the front of the
furnace. The refrigerant and entrance supply opening
dimensions may be adjusted ± 1/2".
3. Cut out the fl oor opening 1/16" larger than the actual
cutout drawn. This will allow some clearance when
installing the duct connector.
FLOOR CUT-OUT
17 1/2" X 14"
FOR UPFLOW
FURNACES WITH
STD. DUCT
CONNECTORS
C L
3/4"
3"
FURNACE
DOOR
20"
1 3/4"
MIN.
FLOOR CUT-OUT
14 1/4" DIAMETER
FOR UPFLOW
FURNACES WITH
ROUND DUCT
CONNECTORS
C L
3/4"
3"
FURNACE
DOOR
20"
REAR WALL OF CLOSET OR ALCOVE
FLOOR CUT-OUT
14 1/2" X 14 1/2"
FOR DOWNFLOW
FURNACES WITH
CONNECTORS
OPTIONAL
REFRIGERANT LINE
10"
4 1/4" X 3 3/4"
STANDARD DUCT CONNECTOR
REAR WALL OF CLOSET OR ALCOVE
FLOOR CUT-OUT
14 1/4" DIAMETER
FOR DOWNFLOW
FURNACES WITH
ROUND DUCT
CONNECTORS
OPTIONAL
REFRIGERANT LINE
10"
4 1/4" X 3 3/4"
ROUND DUCT CONNECTOR
Figure 6. Cut-Out Dimensions for Downfl ow
Furnaces
4. Measure from the top of the fl oor down to the top of the
supply air duct to obtain the depth of the fl oor cavity.
NOTE: The depth of the fl oor cavity shown as "X" in
Figure 7 will determine the correct duct connector.
5. Determine which duct connector to use from Table 2
(page 10).
"X"
SUPPLY AIR DUCT
FLOOR
CAVITY
Figure 7. Floor Cavity
2 3/8" MIN.
STD. DUCT
OPTIONAL SUPPLY
WIRE ENTRANCE
3" X 6 1/4"
C L
3/4"
5"
3 3/8"
FURNACE
DOOR
20"
2 3/8"
MIN.
OPTIONAL SUPPLY
WIRE ENTRANCE
3" X 6 1/4"
C L
3/4"
5"
3 3/8"
FURNACE
DOOR
20"
FLOOR OPENING
9