Write Log Ext (X'3F') [Optional Command (Customize)] - Fujitsu MHV2100AH Product Manual

Disk drive
Hide thumbs Also See for MHV2100AH:
Table of Contents

Advertisement

Interface

(47) WRITE LOG EXT (X'3F') [Optional command (Customize)]

Description
This command writes data to the general-purpose log of a device. The general-
purpose log includes the extended SMART comprehensive error log, extended
self-test log, SMART selective self-test log, and other logs. However, some of
these logs are read-only logs. The types of logs available depend on the customize
operation. For information on the DRQ, INTRQ, and BSY protocols related to the
transfer of data, see Section 5.4.1.
When command is issued (I/O register setting values)
1F7H (CM)
1F6H (DH)
1F5H (CH) P
1F5H (CH) C
1F4H (CL) P
1F4H (CL) C
1F3H (SN) P
1F3H (SN) C
1F2H (SC) P
1F2H (SC) C
1F1H (FR) P
1F1H (FR) C
C: Current
P: Previous
When command is completed (read data in I/O register)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH) 1
H
1F5
(CH) 0
H
1F4
(CL) 1
H
1F4
(CL) 0
H
1F3
(SN) 1
H
1F3
(SN) 0
H
1F2
(SC) 1
H
1F2
(SC) 0
H
1F1
(ER)
H
0: HOB=0
1: HOB=1
5-122
0
0
1
1
x
x
x
DV
xx
xx
Sector offset (15-8)
Sector offset (7-0)
xx
Log address
Sector count (15-8)
Sector count (7-0)
xx
xx
Status information
x
x
x
DV
xx
xx
xx
xx
xx
xx
xx
xx
xx
1
1
1
1
xx
xx
C141-E217

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhv2080ahMhv2060ahMhv2040ah

Table of Contents