Canadian Masonry & Heat Circulating; Leveling Bolts And Sheet Metal Shims - Hearth and Home Technologies 4100I-GD-B Manual

Advanced combustion technology wood insert
Table of Contents

Advertisement

R
(INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA)
Whether installed in a masonry or heat-circulating fireplace, this fireplace insert must be installed with a continuous chim-
ney liner of six inch (152mm) diameter extending from the fireplace insert to the top of the chimney. The chimney liner must
conform to the Class  requirements of CAN/ULC-S65, Standard for Lining Systems for Existing Masonry
Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
• Do not remove bricks or mortar from fireplace to accommodate insert.
• The face of the fireplace must be sealed to prevent room air passage into the chimney cavity.
• The permanent metal warning label provided must be affixed to the back of the fireplace with screws or nails to
the fireplace, in a location readily visible should the fireplace insert by removed, stating that the fireplace may
have been altered to accommodate the insert, and must be returned to original condition for use as a conven-
tional fireplace.
• Circulating air chambers may not be blocked.

LEVELING BOLTS AND SHEET METAL SHIMS

Reach between side of insert and outer skin
Figure 12A
SHEET METAL GUIDES
Slide each guide under the insert on each side placing
them directly under leveling bolts. If they are not directly
under the bolts, the bolts may hang up on uneven material
when sliding the insert into place. See Figure 12B.
Page 12
4100-I ACT WOOD INSERT
INSTALLATION IN CANADA
MASONRY and HEAT-CIRCULATING
cut-out view
Leveling Bolt
This product shipped with two leveling bolts, and two sheet
metal guides for ease in sliding the insert into place when
using the leveling bolts. Not all installations will require the
use of the leveling bolts. The sheet metal guides are used
only when the leveling bolts are necessary. Discard if not
needed.
ADJUSTiNg THE lEVEliNg BOlTS
It is best to use a 1/2 inch (12.7mm) socket wrench with an
extended handle for ease in adjusting bolts to the desired
level. The bolts will adjust from 0 to 2 inches (0 - 51mm).
You can also reach in and adjust the bolts by hand, although
space is limited. Figure 12A.
Place under leveling bolts
and slide insert into place
250-7201E
or Factory-Built
Sheet Metal Shims
Leveling Bolts
Figure 12B
September 1, 2008

Advertisement

Table of Contents
loading

Related Products for Hearth and Home Technologies 4100I-GD-B

This manual is also suitable for:

4100i-nl-b

Table of Contents