- the drive is in dormant mode (i.e. the laser diode is off and spindle motor not spinning, the drive is power on) for
90% of power on time.
3.3 OPTICAL PICKUP ACTUATOR MECHANISM
The drive is capable at least 2,000,000 full stroke seeks.
3.4 MTTR (MEAN TIME TO REPAIR)
30 minutes
4.0 REGULATIONS AND STANDARDS
4.1 SAFETY APPROVAL
UL(UL1950), C-UL(CSA C22.2 No.950), TÜV(EN60950, EN60825-1), CB( IEC 60950,IEC60825-1 )
NEMKO(EN60950,EN60825-1)
4.2 EMC AND COMPLIANCE
CE Marking(EN55022 Class B, EN55024), FCC(ClassB), C-tick(AS/NZS3548 ClassB), BSMI, MIC
4.3 FDA COMPLIANCE
The product satisfies all the requirements specified in the Code of Federal Regulation 21CFR part 1040.10 and
1040.11.
5.0 MECHANICAL
5.1 DIMENSIONS AND MOUNTING ORIENTATION
5.1.1 DIMENSIONS
148.2(W) x 198(L) x 42(H)
5.1.2 WEIGHT
1.06Kg
5.2 IDE CONNECTOR
The drive has a standard 40-pin(2x20) unsealed male connector for IDE signal
6.0 ELECTRICAL
6.1 POWER
6.1.1 VOLTAGE
This drive requires two power supplies : +5V (DC) / +12V (DC).
6.1.1.1 VOLTAGE TOLERANCE
+5V (DC)
+12V (DC)
6.2 IDE SIGNAL INTERFACE
6.2.1 GENERAL
+/– 5%
+/– 10%