How To Exit Eco Mode; Fine Tuning Your Dt92E; Changing The Dt92E Installer Parameters - Honeywell Y9420H Sundial RF2 Pack 2 User Manual

Wireless enabled programmer and wireless room thermostat
Hide thumbs Also See for Y9420H Sundial RF2 Pack 2:
Table of Contents

Advertisement

How to Exit ECO Mode

To exit ECO mode, simply press the green
ECO button again. ECO will disappear
from the display and the thermostat will
control to its previous set temperature.

Changing the DT92E Installer Parameters

The DT92E has a special Installer Mode where some features can be adjusted to suit
your lifestyle or preferences – these are called Installer Parameters, and are listed in
the table below, along with a description of the options that are possible.
Your installer should set this up for you to suit your application (see CONFIGURATION
& SERVICE DATA section). However, you may wish to alter some of the settings
yourself, and this section shows you how to do this.
INSTALLER
PARAMETER
Temperature
measurement offset
Upper setpoint limit
Lower setpoint limit
Energy saving ECO
setpoint
Reset parameters
to factory settings
DT92E ENERGY SAVING ECO FEATURE
Parameter Default
Value
t0
0
uL
35
LL
5
ES
18
FS
1

FINE TUNING YOUR DT92E

Options Description
-3 to 3 K Offset to measured
temperature
21 to
Upper set temperature
35°C
limit in °C
5 to 21°C Lower set temperature
limit in °C
5 to 35°C Energy saving ECO set
temperature in °C
0, 1
Parameter will be set to 0
if any of the other param-
eter values have been
changed. Set to 1 to get
back to factory settings.
23

Hide quick links:

Advertisement

Table of Contents
loading