3. Attention: A second rating plate must be affixed
in acleally visible position on the inside of the
piece of furniture underneath. The recessed plate
must be dismountable.
Electrical connection / feedline
1. The connection can be made directly or via a
socket installed on-site (ensure cable strainrelief
fitted). For direct connections:Allow about 1.2 m
cable length from the wall.
2. The mains connection cable used must be of the
type H05VV-F or of a higher rating.
3. The mains connection is to be carried out so that
threre is the possibility of separating all poles with
a minimum contact opening of 3 mm.
4. The yellow/green earthed conductor flex coming
from the hob is integrated in the 21-pole plug.The
earthed conductor should be checked to ensure
it is connected correctly.
5. The connector boxes attached to the hob wiring
is now inserted in the 21-pole socket board loca-
ted at the rear of the control panel.
6. The control panel is inserted in the opening in the
front wall of the kitchen unit.
Attention: The cable must not touch the cast hot
plate.
Only when the operations described above have
been completed can the fuses be replaced in the
mains supply and the control panel or hob used.
The appliance is only protected against accidental
contact when it has been fully installed in the kitchen
unit. The fuses must only be replaced or the main
switch turned on when installation is complete. The
appliance must be fitted and secured in accordance
with these installation and operating instructions.
We must stress the fact that we accept no liability for
any direct or indirect damage or injury resulting from
incorrect connection or from installation work carried
out by unauthorised persons.
When carrying out service work, the equipment
must be disconnected from the mains supply.