Address - Toshiba RBC-AX22CE Owner's Manual

Remote controller for air conditioner (split type)
Hide thumbs Also See for RBC-AX22CE:
Table of Contents

Advertisement

ADDRESS

When the multiple indoor units corresponding to the wireless remote controller are
installed in the same room, an address can be set up to prevent an interference.
Matching the address switch of the sensor with number of the remote controller ad-
dress, Max. 6 indoor units can be controlled by the corresponding remote controller
individually.
The address switch for receiving the signal is prepared to the sensor (inside of panel or
indoor unit) and the address switch for sending the signal is prepared to the remote
controller. For details, contact the shop which you purchased the air conditioner.
How to Check the Address
When pushing
ADR
display section of the remote controller. If this address matches with the address of the sensor
(inside of panel or indoor unit), a buzzer sounds.
(When ALL is displayed, buzzer sound is necessarily heard.)
When ALL is displayed, the air conditioner can be operated regardless of any address of the
sensor (inside of the indoor unit). Send the signal by directing the remote controller toward the
sensor (panel or indoor unit body) to be handled.
How to Match the Address
Setup to remote controller address
1. When keeping
ADR
section of the remote controller and the present address is displayed with flashing.
2. Every pushing
ADR
one of them with the address switch of the indoor unit sensor to be handled.
3. When pushing
C L
If the address matches with the address switch of the operation part, the buzzer sounds.
Display of
remote
controller
address
Address switch
position of
sensor
Turn the knob to the right side for 1 to 3 while to the left side for 4 to 6 of Address select switch
S001.
button on the remote controller, the present address is displayed on the
pushed for 4 seconds or more,
, the address is exchanged as ALL
, the address display goes on and is displayed for 5 seconds.
Address
Address
* Address switch
of sensor unit
can be set any
position.
lamp goes on at the display
ADR
Address
4–6
4–6
1–3
3
2
1
3
6
5
4
6
11
1
2
3 ...
6
Address
4–6
1–3
2
1
5
4
ALL. Match
1–3
3
2
1
6
5
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tcb-ax21e

Table of Contents