Power amplifier units

Advertisement

Quick Links

INSTRUCTIONS
POWER AMPLIFIER UNITS
UR-PA5000
UR-PA6000
REQUIRED
Before installing the power amplifier unit, one of the following
cables is required.
NOTE: The cables are not
OPC-2202
supplied with the the power
amplifier unit.
• OPC-2202
CONNECTION CABLE
Connects between the repeater
unit and the PA unit.
OPC-2203
• OPC-2203
CONNECTION CABLE
Connects between the repeater
unit, the PA unit and the external
equipment, if used.
SUPPLIED ACCESSORIES
q Set screws (M3×6 mm) ........................................6
w Coaxial cable (OPC-2243) ...................................1
e DC power cable....................................................1
q
w
e
• FOR CLASS A UNINTENTIONAL RADIATORS:
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications.
Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be re-
quired to correct the interference at his own expense.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incor-
porated (Japan) in Japan, the United States, the United Kingdom, Germany,
France, Spain, Russia and/or other countries.
All other products or brands are registered trademarks or trademarks of their
respective holders.
Thank you for purchasing the UR-PA5000/UR-
PA6000
for the IC-FR5000/IC-
POWER AMPLIFIER UNITS
FR6000 series
repeaters.
Please read these instructions and the repeater's
instruction manual carefully before installing the
units and operating the repeater.
OPENING CASE
q Remove the 7 screws from top and the 2 screws
from each side of the repeater, then slide off the top
cover to the direction of the arrow.
P 0
P 1
P 2
P 3
P 4
w Remove the 3 screws from bottom and the 2
screws from each side of the repeater.
P 0
P 1
P 2
P 3
P 4
e Disconnect the control cable from the channel
module, then remove the front panel.
Channel module
Front panel
P 0
P 1
P 2
P 3
P 4
r Remove the 5 screws to remove the
front plate
off.
Front plate
Front panel
LOCATING THE UNIT
Before installing the power amplifi er unit, relo-
cation of the channel module is necessary.
Otherwise, the amplifi er's ventilation system
will not work properly and may damage the
unit.
q Detach the support bracket by removing the set
screws, as illustrated below.
w Detach the channel module by removing the 2 tap-
ping screws and the 3 set screws.
e Reinstall the module on the right side (front view)
of the base with the 2 tapping screws and 4* set
screws.
* Use one of the support bracket's set screws to reinstall.
Support bracket
Channel module
Set screws
Tapping
screws
r Install the power amplifier unit with the fans facing
the front of the repeater.
• Tighten only 5 set screws at this time, as illustrated
below.
Power amplifier unit
Set screws
Channel module
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
t When both module and amplifier are installed, at-
tach the support bracket with the set screws to the
original location, on the amplifier's angle.
• The inmost part of the bracket will be tightened along
with the amplifi er's angle.
Channel module
Power amplifier unit
Support bracket
ASSEMBLE THE UNIT
q Connect the control cable to the channel module.
Channel module
Power amplifier unit
Control cable
P 0
P 1
P 2
P 3
P 4
w Return the front panel, top cover and screws to
their original positions.
P 0
P 1
P 2
P 3
P 4
A-7027H-1EX-w
Printed in Japan
© 2012–2013 Icom Inc.

Advertisement

loading

Summary of Contents for Icom UR-PA5000

  • Page 1 Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incor- Channel module porated (Japan) in Japan, the United States, the United Kingdom, Germany, Front panel France, Spain, Russia and/or other countries.
  • Page 2 POWER SUPPLY CONNECTION LINE FUSE REPLACEMENT Make sure the repeater's power is turned OFF before The UR-PA5000/UR-PA6000 is equipped with 30 A connecting a DC power cable. fuses. If the fuses blow, fi nd and repair the problem, then install new fuses with the same ratings.

This manual is also suitable for:

Ur-pa6000