Product Specifications
4.8

Environmental Limits

PARAMETER
Temperature
Thermal Gradient
Relative Humidity
Wet Bulb
Altitude (relative to sea
level)
2
Acoustic Noise
Fluid
Bearing
1 Disk
2 Disk
3 Disk
Notes:
1. Margin Demonstrated implies the product will operate at the stated conditions
with an acceptable impact to the ARR specification for any OEM requiring
those values in their purchase specification.
2. The testing performed by Maxtor is consistent with ISO 7779. Variation in
acoustic levels from the idle specification may occur due to offline activity
according to the SMART specification and/or atmospheric conditions.
4-6
DiamondMax 10 80/100/120/160/200/250/300GB Serial ATA
OPERATING
0×C - 60×C
The drive temperature is
measured at the base plate
motor well.
25 C per hour (maximum)
5% to 95% (non-condensing)
37.7 C (maximum)
-650 to 10,000 feet
IDLE MODE
Bels
Avg
2.5
2.6
2.9
NON-OPERATING/
STORAGE
low temperature (-40 C)
high temperature (71 C) per
MIL-STD-810E, method 501.3,
climatic category; hot-induced
conditions.
-650 to 40,000 feet
NORMAL
QUIET SEEK
SEEK MODE
Bels
Avg
3.2
3.8
3.8
MODE
Bels
Avg
2.6
2.7
3.0