Built-In Dimensions; Built-In - Zanussi ZKF 65 LN Operating And Installation Instruction

Electric ceramic-glass hob
Table of Contents

Advertisement

When building in ceramic glass cooking areas the front
cross-rail of the build-in cupboard must be removed in
order to have the heat radiating off escape without any
obstacles.
The space under the hob unit must be closed at all
sides in a way that the lower side of the cooking area
is no longer accessible.
The distance from the hob to the furniture part under
the hob must at least amount to 20 mm. If needed,
please fix an insulation. Drawers must not be located
under a hotplate.
The distance from the hob to a high cupboard beside
right or left must at least amount 55 mm, to the back
wall at least amount 55 mm.
With regard to the protection against overheating of
surrounding furniture surfaces this appliance corres-
ponds to type Y (EN 60335). This appliance or the
built--in cupboard for the appliance respectively may be
located with the rear wall and one side wall to whatever
high walls or furniture respectively and with the other
side to another appliance or furniture of the same
height as this appliance.

Built-in dimensions

The opening in the worktop must correspond to com-
mercial dimensions. The hints required are given in the
dimension sketch.

Built-in

Cut out the worktop acc. to prescribed cutout size. The
tolerance sizes must not be exceeded. Do precisely
saw at the mark line. Recommendation: Mark the cut-
out with a steel needle. Glue something on the line in
order to avoid shattering of the coat when cutting.
With tile--coated worktop areas the slits in the support-
ing area for the cooking area must be filled up com-
pletely.
Clean the worktop in the cutout area
From the top lay the cooking area into the cutout, adjust
concentrically and firmly press down.
Check the sealing in the supporting frame for perfect
seating and resting without a gap. Please do not apply
additional silicone sealing material, the closure will
make it harder to dismantle in case of need for service.
5 holes in the bottom of the build--in case are provided
for the screws of the fitting plates.
At first screw on the fitting plates by a screwdriver and
afterwards regularly tighten the plates alternatively and
diagonally offset, until the frame of the cooking area is
perfectly laying on the worktop.
A too strong and one--sided tightening is to be avoided!
Electric screwdrivers or pusher airscrews to be exclu-
sively used with slip clutch (setting value 1 -- 1.1 Nm).
Measurement of
Worktop opening:
width: 560 mm
depth: 490 mm
radius:
5 mm
Voltage:
Total connected load:
502
Frame measurement
on worktop 9 mm
Points for fixing clamps
560 ±1
hobs frame
worktop
fixing clamp
20
Appliance:
width:
572 mm
depth: 502 mm
heigth : 49 mm
AC 230 V 50 Hz/60 Hz
5.9 kW
572
heigth of the hob
49 mm
R5
490 ±1
1
2
ceramic glass plate
49 mm
heigth of frame
over worktop
3 mm