Electric connection

The mains connection must be carried out by an expert
electrician. The VDE-regulations and the valid pre-
scriptions by the local power suppy boards have to be
compiled with.
Prior to connection it should be checked whether the
voltage stated on the type plate -- i.e. the nominal vol-
tage of the appliance and of the oven/control box -- is
identical with the prevailing mains voltage. The type
plate ist located on the hobs bottom.
The heating element voltage amounts to 230 V . The
appliance will also perfectly perform with the former
mains voltage of 220 V .
The mains connection must be carried out in a way that
an all--pole insulating device is existing with a contact
opening of at least 3 mm, e.g. LS--automatism, earth--
leakage circuit--breaker or fuse.
A wire of type H05VV-F or of higher rating is to be used
as supply cable.
The mains terminal is located in the bottom of the
appliance behind a covering slide.
According to existing mains voltage the appliance has
to be connected in correspondence with the diagrams
of connecting possibilities. The bridges of the terminal
board are to be changed accordingly, if need be.
The protective conductor is to be connected to terminal
. The protective conductor must be longer than live
leads.
The cable connections have to be established as
prescribed and the terminal screws be firmly tigh-
tened.
Afterwards the supply cable has to be secured by strain
relief device and the covering slide must be closed.
Prior to first use remove any possibly existing labels
and protective foils from the ceramic glass plate or the
frame of the hob.
After connection to the power supply all hea-
ting elements are to be switched on shortly at
maximum setting one after another, in order to
check the operability.
Open the connection ter-
minal with a screw driver
strain relief device
Electrical connection 230 V ~
1
2
L1
1
2
L1
1
2
L1 L2
1
2
(L3)
L1
1
2
L1
21
Changeing
connection
bridges
3
4
5
N
3
4
5
400 V 2 N ~
L2
N
3
4
5
400 V 3 N ~
L3
N
3
4
5
L2
3
4
5
L2
L3
230 V ~
1 L + N
2 L + N
3 L + N
230 V 2 ~
2 L
230 V 3 ~
3 L