Sony TRINITRON KV-ES34M81 Service Manual page 43

Ag3 chassis
Hide thumbs Also See for TRINITRON KV-ES34M81:
Table of Contents

Advertisement

4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then
use the BMC magnet to adjust in the manner described below.
R G
B
R
R
B
R
G
5
Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN]
and [BRIGHTNESS] to [STANDARD] .
2. Adjust the Y separation axis correction magnet on the neck
assembly so that the horizontal lines at the top and bottom of
the screen are straight.
Blue
Neck assy
Red
VM board
Note
1. The Red and Blue magnets should be equally far from the
horizontal center line.
2. Do not separate the Red and Blue magnets too far. (Less than
8 mm)
G
B
R
G B
G
B
G
R
B
Red
Neck assy
Blue
VM board
(2) Dynamic Convergence Adjustment
Preparation:
Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
Set the PICTURE and BRIGHTNESS to normal.
1. Adjust TLH. (TLH correction piece)
1 Receive the dot/hatch pattern signal and adjust picture quality
by the menu.
2 Correct horizontal mis-convergence of red and blue of both sides
on the X axis.
When red is outside insert BMC magnet to right side (THL+)
views from DY neck. And when blue is outside, insert it to left
side (THL–) and take both sides.
R
B
(B)
(R)
(R)
2. Adjust V TILT-TLV (TLV 34")
Correct the vertical mis-convergence of red and blue of verti-
cally sides on the Y axis.
3. Adjust YCH.
Adjust horizontal mis-convergence of red and blue of verti-
cally sides on the Y axis. Mentioned above steps 2 to 4 are
adjusting respectively perform minuteness tracking.
YCH
VM board
– 43 –
KV-ES34M81/ES34M91
B
R
TLH +
(B)
TLH -
H-TRP
TLV
BMC magnet
C board
RV9001
RM-916

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron kv-es34m91

Table of Contents