Carrier 40GVC Owner's Manual page 9

High-wall ductless split system sizes 009 - 024
Hide thumbs Also See for 40GVC:
Table of Contents

Advertisement

INDOOR UNIT
Clean Air Filter*
Change Remote Control Batteries
OUTDOOR UNIT
Clean Outdoor Coil from Outside
Clean Outdoor Coil from Inside†
Blow Air Over Electric Parts†
Check Electric Connection Tightening†
Clean Fan Wheel†
Check Fan Tightening†
Clean Drain Pans†
* Increase frequency in dusty zones.
{ Maintenance to be carried out by qualified service personnel. Refer to the Installation Manual
PROBLEM
Indoor unit emits a bad odor on
start- - up
You hear water flowing noise
when the unit is running
Indoor unit produces a mist
when the air conditioner is
running
Wireless remote control does
not work
Water leaks into room from
Indoor unit
Unit/System Does Not Work
Cooling is Not Working
Properly
Heating is Not Working
Properly
Unit Stops During Operation
Table 1—Periodic Maintenance
EVERY MONTH
S
EVERY MONTH
Table 2—Troubleshooting
POSSIBLE CAUSE
 Air filter dirty
 Output air still has odor after cleaning filter.
 This is normal and is the refrigerant flowing
through the system.
 This is normal cooling and is caused by high
humidity and temperature in the room.
 Batteries are dead.
 Unit needs to be reset.
 Condensing water has overflowed
 To protect the unit upon an immediate restart
after a stop, the system controller will delay
the unit for 3 minutes before allowing the unit
to start back up.
 The circuit breaker has tripped or a fuse
has blown.
 Power failure.
 Error codes displayed
 Voltage is too low.
 The filter is blocked with dust.
 Temperature is not set properly.
 A window or door is open.
 The outdoor unit is obstructed.
 The fan speed is too low.
 The operation mode is in Fan instead of
Cool.
 The filter is blocked with dust.
 Temperature is set too low.
 A window or door is open.
 The outdoor unit is obstructed.
 The Off timer is not operating correctly.
 Error codes displayed
EVERY 6 MONTHS
S
EVERY 6 MONTHS
S
 Clean the air filter
 Contact your service representative.
 No maintenance required
 No maintenance required. Mist should stop as
room is cooled down and the humidity is removed.
 See battery replacement section in this manual
and replace batteries.
 Turn off power to indoor unit. Remove plug from
wall and then reinsert plug. Restart unit.
 Check indoor condensing drain or call your
representative.
 After turning unit off, wait at least 3 minutes before
trying to restart.
 Reset the circuit breaker or replace the fuse with
the specified replacement fuse.
 Restart operation when the power is restored.
 Call your service representative.
 Call your service representative.
 Clean the air filter.
 Check the temperature and reset if necessary.
 Close the window or door.
 Remove the obstruction.
 Change the fan speed selection.
 Change the operating mode to Cool or reset the
unit.
 Clean the air filter.
 Check the temperature and reset if necessary.
 Close the window or door.
 Remove the obstruction.
 Restart the operating mode.
 Call your service representative.
9
EVERY YEAR
S
EVERY YEAR
S
S
S
S
S
S
SOLUTION