Blower Accessory Information - Empire Comfort Systems DVL25IN73N-1 Owner's Manual

Direct vent gas fireplace heater
Table of Contents

Advertisement

BLOWER ACCESSORY INFORMATION

The appliance, when installed must be electrically con-
nected and grounded in accordance with local codes or,
in the absence of local codes, with the current CSA C22.1
Canadian Electrical Code.
U.S. Installations, follow local codes and the National
Electrical Code, ANSI/NFPA No. 70.
Should this blower require servicing, the power supply
must be disconnected. For rewiring of any replacement
components, refer to Figures 16 and 17 and the parts list
on pages 30-31.
BLOWER ACCESSORY
Operation
The fireplace insert is equipped with a factory installed blower
accessory that includes a fan control switch, plus a rheostat
(speed control).
The speed control knob is located in the lower compartment at the
right side of the insert.
From a cold start, the temperature activated fan control switch will
normally take 5-10 minutes to heat up and energize the blower.
Once the blower is energized, adjust the blower speed control as
desired.
When the insert is shut off, it may take 30-40 minutes for the
heated unit to dissipate (cool down) enough for the blower to shut
off automatically. NOTICE: The blower shut off times will vary on
blower speed and BTU input level setting control by adjustment of
the HI/LO knob located on the gas valve.
Blower removal instructions
Servicing or removal of the blower system must be performed by
a qualified service person.
If the blower assembly must be replaced, the following steps are
recommended for removal:
1.
Turn off gas and disconnect the electrical supply.
2.
Remove the front surround panel assembly by pulling bottom
forward, then upward to detach.
3.
Release the two (2) spring latches at the top and two (2) spring
latches at the bottom to remove the glass door assembly.
4.
Remove decorative glass from burner cover if used.
5.
Remove the 5/16" x 2-1/2" center bolt that retains the Vent
Slide plate assembly.
6.
Remove the insert from the fireplace cavity by pulling forward
on the insert, and at the same time, sliding the vent plate
rearward until disengaged.
7.
As the insert is moved outward, the gas line may need to be
disconnected at the insert shut off valve. If so, make sure the
main gas line is shut off that supplies gas to the insert.
8.
Once the insert is pulled out, the blower assembly can be
removed by locating the (6) screws on the lower back of the
insert that retains the blower base plate.
9.
When the screws are removed, gently pull the blower assembly
outward.
10. Disconnect the two ¼" wire terminals from the motor.
11. Remove the (4) screws that retain the blower assembly to the
base plate, and set blower aside.
12. Install the replacement blower, and re-install the insert by
reversing above steps.
Page 16
BLOWER ASSEMBLY
FAN CONTROL
SWITCH
MILLIVOLT
VALVE SHOWN
PIEZO IGNITOR
(MILLIVOLT ONLY)
FAN SPEED CONTROL
REMOTE/OFF/ON SWITCH
(MILLIVOLT ONLY)
Figure 16
Figure 17
29209-0-0911

Advertisement

Table of Contents
loading

Table of Contents